ZyXEL Communications ES3500-24 User Manual page 88

Layer 2 management switch
Hide thumbs Also See for ES3500-24:
Table of Contents

Advertisement

Chapter 8 Basic Setting
The following table describes the labels in this screen.
Table 12 Basic Setting > IP Setup
LABEL
Domain Name
Server
Default Management IP Address
DHCP Client
Static IP Address
IP Address
IP Subnet Mask
Default Gateway
VID
Apply
Cancel
Management IP Addresses
You can create up to 64 IP addresses, which are used to access and manage the Switch from the ports
belonging to the pre-defined VLAN(s). You must configure a VLAN first.
IP Address
IP Subnet Mask
VID
Default Gateway
Add
Cancel
Index
IP Address
IP Subnet Mask
VID
Default Gateway
88
DESCRIPTION
DNS (Domain Name System) is for mapping a domain name to its corresponding IP
address and vice versa. Enter a domain name server IP address in order to be able to
use a domain name instead of an IP address.
Select this option if you have a DHCP server that can assign the Switch an IP address,
subnet mask, a default gateway IP address and a domain name server IP address
automatically.
Select this option if you don't have a DHCP server or if you wish to assign static IP
address information to the Switch. You need to fill in the following fields when you
select this option.
Enter the IP address of your Switch in dotted decimal notation for example
192.168.1.1.
Enter the IP subnet mask of your Switch in dotted decimal notation for example
255.255.255.0.
Enter the IP address of the default outgoing gateway in dotted decimal notation, for
example 192.168.1.254.
Enter the VLAN identification number associated with the Switch IP address. This is the
VLAN ID of the CPU and is used for management only. The default is "1". All ports, by
default, are fixed members of this "management VLAN" in order to manage the device
from any port. If a port is not a member of this VLAN, then users on that port cannot
access the device. To access the Switch make sure the port that you are connected to is
a member of Management VLAN.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top
navigation panel to save your changes to the non-volatile memory when you are done
configuring.
Click Cancel to begin configuring the fields again.
Enter the IP address for managing the Switch by the members of the VLAN specified in
the VID field below.
Enter the IP subnet mask in dotted decimal notation.
Type the VLAN group identification number.
Enter the IP address of the default outgoing gateway in dotted decimal notation.
Click Add to insert the entry to the summary table below and save your changes to the
Switch's run-time memory. The Switch loses these changes if it is turned off or loses
power, so use the Save link on the top navigation panel to save your changes to the
non-volatile memory when you are done configuring.
Click Cancel to reset the fields to your previous configuration.
This field displays the index number of the rule. Click an index number to edit the rule.
This field displays the IP address.
This field displays the subnet mask.
This field displays the ID number of the VLAN group.
This field displays the IP address of the default gateway.
ES3500-24 User's Guide