To interface the CL-410/CL-420 with a home theater automation/control system or a PC
running terminal emulation software, connect it to your control system or PC as shown in
Figure 3-11.
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to 9600, to match that of the CL-410/CL-420
RS-232 port.
Table 6-1 lists the RS-232 command set. All commands are in ASCII format and must be
in UPPERCASE.
When you send a valid command, the CL-410/CL-420 executes it and acknowledges it
with the first three characters of the command followed by "OK;" for example, "RRAOK."
When you send an invalid command, the CL-410/CL-420 ignores it and returns the first
three characters of the command followed by "NG;" for example, "RRXNG."
Table 6-1. Serial Commands
Command
RRA00
Saves current settings to the CUSTOM 1 memory
(Note 1)
RRA01
Saves current settings to the ISF Day memory
(Note 1)
RRA02
Saves current settings to the ISF Night memory
(Note 1)
RRB00
Recalls the Custom 1 memory settings
RRB01
Recalls the ISF Day memory settings
RRB02
Recalls the ISF Night settings
RRC00
Selects the S-VIDEO input
RRC01
Selects the COMPOSITE VIDEO input
RRC02
Selects the COMPONENT 1 input
RRC03
Selects the COMPONENT 2 input
RRC04
Selects the HDMI input
RRC05
Selects the RGB input
Notes:
1. All image quality settings must be made with the remote control. After the image adjustments
are complete, you can use these commands to store the settings in the selected memory.
2. The power on command (PON) will not provide an OK reply; it will instead reply with a random
character. For your automation system, simply ensure that you receive a character after the
PON command. If you do not get any reply after PON, send PON again.
Runco CL-410 and CL-420 Owner's Operating Manual

6. Serial Communications

Description
53
6.1
RS-232 Connection
and Port Configuration
6.2
Serial Command
Syntax
Reply
RRAOK
RRAOK
RRAOK
RRBOK
RRBOK
RRBOK
RRCOK
RRCOK
RRCOK
RRCOK
RRCOK
RRCOK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl-410

Table of Contents