Cisco ASR1004 - ASR 1004 Modular Expansion Base Hardware Installation Manual page 166

Aggregation services routers sip and spa
Hide thumbs Also See for ASR1004 - ASR 1004 Modular Expansion Base:
Table of Contents

Advertisement

Troubleshooting the Hardware
Table 7-3
Possible Problems and Solutions for Hardware-Based Out-of-Service States on the Cisco WebEx Node SPA
and SPA-DSP (continued)
Possible Problem
Observations and Comments
Temperature or
Execute the show hw-module subslot sensors command
voltage sensors
for a SPA-DSP to display the actual values for the
have values that are
temperature and voltage on the SPA-DSP, as shown in the
not in the range of
following example:
safe operation for
Router# show hw-module subslot 0/2 sensors
the Cisco WebEx
SPA-DSP[0/2] temperature sensor 0, reading: 43C
Node SPA and
SPA-DSP[0/2] temperature sensor 1, reading: 38C
SPA-DSP.
SPA-DSP[0/2] temperature sensor 2, reading: 44C
SPA-DSP[0/2] nominal: 3.300V, reading: 3.275V
SPA-DSP[0/2] nominal: 2.500V, reading: 2.517V
SPA-DSP[0/2] nominal: 1.800V, reading: 1.786V
SPA-DSP[0/2] nominal: 3.300V, reading: 3.293V
SPA-DSP[0/2] nominal: 1.200V, reading: 1.194V
SPA-DSP[0/2] nominal: 1.000V, reading: 0.993V
Execute the show hw-module subslot sensors limit
command for a SPA-DSP to compare the warning, critical,
and shutdown temperatures and voltage values with actual
values. The show hw-module subslot sensors limit
command not only displays the actual voltage and
temperature values, but also provides the temperature and
voltage limit values for the warning, critical, and shutdown
states for a sensor.
Router# show hw-module subslot 0/2 sensors limits
Temperature sensors for SPA-DSP[0/2]:
Sensor
Shutdown
0
1
2
Voltage sensors for SPA-DSP[0/2]:
Nominal
HighShut
3.300V
3.630V
2.500V
2.750V
1.800V
1.980V
3.300V
3.630V
1.200V
1.320V
1.000V
1.100V
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide
7-6
Reading
Low
Warning
43C
-5C
70C
38C
-5C
62C
44C
-5C
67C
Reading
LowShut
LowWarn
3.278V
2.970V
3.069V
2.517V
2.250V
2.325V
1.785V
1.620V
1.674V
3.293V
2.970V
3.069V
1.194V
1.080V
1.116V
0.993V
0.900V
0.930V
Solutions
Tip
Critical
85C
91C
77C
83C
82C
88C
HighWarn
3.531V
2.675V
1.926V
3.531V
1.284V
1.070V
Chapter 7
Troubleshooting the Installation
Use the WebEx Node solutions
mentioned above for SPA-DSP.
OL-14126-12

Advertisement

Table of Contents
loading

Table of Contents