1. Under no circumstances can the gas soundness be checked by means of a naked
flame (e.g. with a match or candle). Danger of explosion!
2. Regularly, every six months, check the condition of the tube and soundness of its
connection to the end elements.
REPLACING THE NOZZLES
Note:
1. Before replacing the nozzles and adjusting gas taps remove the cable plugfrom
the mains supply .
2. When adjusting the taps do not unscrew the needle completely.
The hob is adjusted to the type of gas and pressure stated on the appliance's rating plate.
In the event of a change of the type of gas replace the nozzles and adjust the taps.
Before beginning these activities you must:
shut down the cock shutting off the gas
supply system or cylinder from the
hob,-shut down all the taps in the hob,
disconnect the hob from the mains.
Then:
remove the burners' lids and rings,
remove the nozzles with socket wrench
no. 7 and replace them with new ones
in accordance with table2,
put burners' rings and lids back,-
adjust the taps and check the
connections for soundness
ADJUSTING THE TAPS
The adjustment of a gas tap consists in setting the burner flame in the simmering position. To
adjust the taps remove all the knobs and control panel.
Then:
– open the gas flow with a knob and light the adjusted burner,
– set the knob in the simmering position
remove it from the tap's mandrel
– put a screwdriver in opening 'A" or mandrel opening "B" (depending on the type of the tap
fig. 10) and turn it, observing the flame, to achieve such a size of the flame that will
prevent it from being extinguished in a slight draught or during the operation of quick
switching from the full
adjustment is correct when the core of the flame is cone-shaped in green and blue colour
and is ca. 2 - 4mm tall,
EN
. and then, without changing that position,
to the simmering position
9