List of Parameters (ZS-HLDC)

List of Parameters (ZS-HLDC)
The following parameters can be obtained or set by DATASET or DATAGET command:
Unit No.
0
0
12
14
13
15
24
26
25
27
18
19
20
22
23
32
192
193
1
0
2
0
2
ZS-Series
12
Non-procedural Communication Command Reference
Data No.
Parameter
Measurement mode
Measurement mode
Start position of area 1
End position of area 1
Start line of area 1
End line of area 1
Start position of area 2
End position of area 2
Start line of area 2
End line of area 2
Exposure time
Number of additional
lines
Line skipping
2-area mode
Compensation mode
Measurement cycle
Reference point teach for
compensation mode
2-area teach
Head installation
LD power mode
Surface to be controlled
for light amount
Setting range/Output range
0: STANDARD
1: HI-RESO
2: HI-SPEED
3: HI-SENS
4: CUSTOM
1: STANDARD
2: HI-RESO
3: HI-SENS
4: CUSTOM
0 to 639 (pix)
0 to 639 (pix)
0 to (No. of additional lines - 1)
0 to (No. of additional lines - 1)
0 to 639 (pix)
0 to 639 (pix)
0 to (No. of additional lines - 1)
0 to (No. of additional lines - 1)
2 to 200 (1 div: 0.1ms)
When multi-task mode is OFF.
5 to 200 (1 div: 0.1ms)
When multi-task mode is ON.
1 to 200
When multi-task mode is OFF.
8 to 200
When multi-task mode is ON.
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: Start position compensation
2: End position compensation
3: Start/End position
compensation
112 to 20000 (us)
1: Execute teach
1: Execute teach
0: Diffuse
1: Regular
0: Auto
1: Auto-scale
2: Fixed
0: Peak
1: First surface
2: Second surface
3: Third surface
Others
When multi-task mode
is OFF.
When multi-task mode
is ON.
Parameters for
CUSTOM mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents