Omron ZS Command Reference Manual page 35

Smart sensors non-procedual communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

In case of ZS-MDC
A maximum of 9 data can be accumulated.
Unit No.
Data No.
124
5
6
7
8
9
10
11
12
13
Increasing data to be accumulated extends the measurement cycle of the ZS controller. Confirm it
by selecting [SYSTEM]-[INFO]-[CYCLE] after setting.
Parameter
Accumulated data 1
Accumulated data 2
Accumulated data 3
Accumulated data 4
Accumulated data 5
Accumulated data 6
Accumulated data 7
Accumulated data 8
Accumulated data 9
Non-procedural Communication Command Reference
FLOWDATA Reference
Description
0: No accumulation
1: Measurement result of TASK 1
2: Measurement result of TASK 2
3: Measurement result of TASK 3
4: Measurement result of TASK 4
5: Measurement result of Input A
6: Measurement result of Input B
7: Measurement result of Input C
8: Measurement result of Input D
9: Measurement result of Input E
10: Measurement result of Input F
11: Measurement result of Input G
12: Measurement result of Input H
13: Measurement result of Input I
ZS-Series
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents