Section 4
Inspecting by the Size (Area)

Basic Setting Procedure

■ Teaching
Teaching is performed after the object and color to be inspected are specified.
Application and Setting Examples p.152
■ Adjusting the threshold level
Threshold values are adjusted to determine the range for OK judgments.
Adjust the threshold values referring to the currently indicated measurement results.
Adjustment of the threshold values must be performed in ADJ mode.
● AREA1/AREA2/AREA3
● Switching to ADJ
mode
MENU
Upper/lower limit
Setting item
Area value
ZFV-C
68
User's Manual
Inspection
area setting
AREA2
OK
1
point
ITEM
REG.
PICK.
● Adjusting of area value
AREA1
ADJ
1
point
RUN
L: [ 80] H:[ 120] B
Lower limit
Range
0 to 999
This is the range for OK when the value at teaching is taken to be 100 %.
If AREA2 is selected, the same judgment conditions will be used for all the four
colors. Judgment is made based on the color, among the four colors, that has the
largest difference from the reference value.
Color Selection
Teaching
TEACH/PICK
1
point
:VOID
SEL
D:HIST
OK
Measured values
80
LEFT/RIGHT keys: Select upper limit/
Upper limit
UP/DOWN keys:
Details of Adjustment
lower limit.
Change values.