Specifying the Amplifier Unit to Input the Trigger
Set whether or not to input the TRIG signal to an Amplifier Unit.
MENU mode-[SYS2]-[LINKSET]-[TRIG]
Setting
I/O (default)
LINK
Setting the Presence of Sensor Head
Set whether or not a Sensor Head is connected.
MENU mode-[SYS2]-[LINKSET]-[HEAD]
Setting
USE (default)
NOT USE
Setting Output Content
Set the output content of the measurement result output cable.
This item is displayed only the Amplifier Unit whose [TRIG/TRIG] setting is set to [I/O].
MENU mode-[SYS2]-[LINKSET]-[OUTPUT]
Setting
ALL
EACH (default)
Output image p.115
Setting for Amplifier Unit Gang-Mount
Set to only the Amplifier Unit to which the TRIG signal is to be input.
Synchronizes to the TRIG signal from the Amplifier Unit gang-mounted on the
right side.
All the Amplifier Units except for the rightmost one are set to [LINK] automati-
cally.
Select this for Amplifier Unit to which a Sensor Head is currently connected.
Measurement is performed using the input image from the currently connected
Sensor Head.
Select this for Amplifier Unit to which a Sensor Head is currently not con-
nected.
Measurement is performed from the image transferred from the Sensor Head
gang-mounted on the right side.
The measurement results of all gang-mounted Amplifier Units are integrated,
and output as an overall judgment result.
The measurement result of each Amplifier Unit is output from the respective
Amplifier Unit.
Details
Details
Details
Section 5
ZFV-C
111
User's Manual