5-10 Termination Code List

The meanings of termination code of response are described below.
Type
Termination Code
Normal end
"00"
Host commu-
"10"
nication
error
"11"
"12"
"13"
"14"
"15"
"18"
Tag communi-
"70"
cation error
"71"
"72"
"74"
"7A"
"7D"
"7E"
"7F"
System error
"7C"
"9A"
5-24
Name
Normal end
Parity error
Framing error
Overrun error
FCS error
Format error
Execution status error
Frame length error
Communication error
Verification error
No-tag error
Outstanding tag error
Address designation
error
Write protect error
ID system error (1)
ID system error (2)
Antenna section error
EEPROM error
Description
Command execution has ended correctly. A command
was executed correctly when polling process is speci-
fied.
A parity error has occurred in any character of com-
mand.
A framing error has occurred in any character of com-
mand.
An overrun error has occurred in any character of com-
mand.
FCS of received command is invalid.
A command format is incorrect. Character interval has
exceeded a preset time.
Communication designation is SI/RI/PI when input set-
ting is RESET. The "MO" command was executed
when no operating condition is registered.
A command string more than 300 characters was
received.
An error has occurred during the communication with a
tag and the communication cannot be completed cor-
rectly.
A correct data cannot be written into a tag (only when
verification is enabled).
There is no tag in a communication area of antenna
when a trigger system command is executed. In a com-
mand which performed communication designation of
"st", there is no tag, which communicated immediately
before, in a communication area of antenna. The
antenna is not connected.
In polling query, a communication process has not yet
been completed.
Designation of process address is unsuitable and the
execution is impossible.
Something was written into a write-protected page.
A tag cannot execute a command process.
An inapplicable tag was used.
No communication can be executed due to antenna
trouble.
An error in writing into/reading from nonvolatile memory
in the controller (the SP/SE command). The "MO" com-
mand was executed under invalid operating condition.