5-8-3 Reset (XZ)

Aborts all the controller processes and performs "Power ON" initial process. There is no response.
<Command>
Command
code
"XZ"
<Response>
Nil

5-8-4 Controller Control (CC)

Changes or obtains the state of external I/O of controller.
<Command>
Command
Process code
External out-
code
put information
"CC"
Process code
External output informa-
tion
<Response>
Termination
Command
Retrans-
code
code
mission
"CC"
flag
External input informa-
tion
External output informa-
tion
Fixed to "00" (I/O control).
Specifies the output of external output 1 and external output 2.
"0": No change
"1": Turned OFF forcibly.
"2": Turned ON forcibly.
Status
External input
External output
flag
information
information
Returns the signal status when a command of external input has been received. (The sec-
ond character is always "0".)
"0": "OFF"
"1": "ON"
Returns the signal status when a command of external output 1 and external output 2 has
been received.
"0": "OFF"
"1": "ON"
5-8 Controller Control Command