From Trial Operation To Communications - Omron V640 - MANUAL 2 User Manual

V640 series
Hide thumbs Also See for V640 - MANUAL 2:
Table of Contents

Advertisement

■ From Trial Operation to Communications

Errors are indicated by the status of the indicators after transmission of the write command, and by the
response code of the response.
Error occurrence
Write command sent
RUN-LED is OFF
No
Is the response
code 1
No
Is the response
code 7
No
Communications OK
• If the ID Tag was processed normally:
Indicators
RUN
COMM
(Lights once)
Response code for the response
Response
Type
code
Normal
00
The ID Tag was processed normally.
If there is no response to the write command, refer to the From Installation to Trial Operation,
Operation Check Flowchart.
Yes
Yes
?
Yes
?
NORM
ERROR
(Lights once)
Refer to page 99.
An error has occurred at the Amplifier Unit.
Amplifier Unit error
Check the command format.
If the response code is 1
Communication with the ID Tag has failed.
If the response code is 7
Function
SECTION 5
Troubleshooting
Refer to page 102.
Refer to page 102.
Refer to page 102.
CIDRW System
User's Manual
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

V640-ham11-v2V640-hs61V700-l22V700-l11

Table of Contents