SECTION 3
Preparing for Communications
Set the parameters for the communications conditions
Specify the parameters whose settings are to be changed from the terminal software of the host
device. The commands, and the parameters that can be set are indicated below.
List of Commands
Designation
Parameter designation
Parameter confirmation ::END
Comment
Tag Name List
Classification
Protocol
SECS
Operation
The setting mode commands do not conform to SEMI standards.
For the terminal software, use Hyper Terminal, which is standard with Windows, or a similar program.
CIDRW System
50
User's Manual
Command Input
(Tag name) = (Set value) <CRLF> Specify the parameter value corresponding to the tag name.
# (Comment) <CRLF>
or
CRLF
Parameter
Baud Rate
Device ID
Time-out between characters
Protocol time-out
Response time-out
Time-out between blocks
Retry limit
Master/slave
Double block detection yes/no S_DB
Source ID
Single block No.
Baud rate for communications
with Amplifier Unit/Link Unit
Number of heads count pro-
cessing
Checks the parameter designations that have been received so
far and, if there is no error, confirms the settings.
This is ignored as the comment line.
Tag name
Setting range
S_BAUD
1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
S_DEVID
0 to 32767
S_T1
0.1 to 10 s
S_T2
0.2 to 25 s
S_T3
1 to 120 s
S_T4
1 to 120 s
S_RTY
0 to 31
S_MS
M: Master
S: Slave
1: The header of the block currently being
received is compared with the correct block
received immediately before, and double
blocks are detected.
0: Double block detection is not performed.
S_SRC
0 to 32767
S_BNO
0, 1
C_BAUD
9600, 19200, 38400 bps
Use a consistent baud rate setting within the
same system configuration.
C_HEAD
0 to 31
0:
The number of heads is automatically
detected at the start. Any increase or
decrease in the number of heads is auto-
matically detected.
1 to 31: The number of heads is specified. The
number of heads detected is compared
with this specified number of heads. If the
number of heads changes, for example
because a head fails, an error (with
alarm) is detected.
If a head is not connected or an error is
detected with a connected head, so that
the number of heads does not match the
specified number, an error (with alarm) is
detected.
Explanation
Default
setting
9600 bps
0
0.5 s
10 s
45 s
45 s
3
M
0
0
1
9600 bps
0