Error Message Tables

5-3
Error Message Tables
When a Project Is Newly
Created
During System Setup
5-4

Precautions When Replacing the PT

Error message
The combination of
An attempt was made to
the selected PT
select a version not supported
model and system
by NSH5-SQ
version is invalid.
Error message
There is an error in
An illegal address or other
the communications
than a bit address has been
address input format.
set for the key status monitor
address (emergency stop,
function switches F3, F4, F5,
F8, F9, F10).
An illegal address or other
than a word address has been
set for the station status moni-
tor address.
$SB cannot be spec-
$SB was specified for the sta-
ified.
tion status monitor address.
$SW cannot be
$SW was specified for the sta-
specified.
tion status monitor address.
Specify a PT mem-
An address not in the PT
ory address.
memory was specified for the
station status monitor
address.
The combination of
An attempt was made to con-
the selected PT
vert a project that is being
model and system
edited to a PT model that is
version is invalid.
not supported.
If a fault is discovered in the inspection and the PT must be replaced, observe
the following precautions.
• Before replacing the PT, back up all of the PT's project data. If the PT is
repaired by OMRON, the project data may be deleted.
• Before replacing the PT, be sure to turn OFF the power supply.
• After replacing the PT, check to be sure that there are no errors in the new
PT.
If the PT is to be returned to OMRON for repair, attach a document to the PT
describing the problem in as much detail as possible, and send the PT to an
OMRON representative listed at the end of the manual.
Contents
Select a version to match the
PT.
@
-V2.
Contents
Check the key status monitor
address and correct the
address that was set.
Check the station status moni-
tor address and correct the
address that was set.
Set an address other than
$SB.
Set an address other than
$SW.
Check the station status moni-
tor address and set an
address in the PT memory.
Select a version that matches
the PT model.
Section 5-3
Countermeasure
Countermeasure
67