Installation

Note
4-4
Installation
Dimensions
Mounting to a Panel
Note
Always turn OFF the Removable Box's key switch before setting the DIP
switch or the rotary switch.
39.5
86
94
100
50
42.5
The Removable Box can be installed using any of the following three meth-
ods.
To mount the Removable Box on a panel, use the mounting brackets and tool
(Phillips screwdriver) that are included in the package.
(1) Do not allow metal particles to enter the Removable Box while work is be-
ing done on the panel.
(2) The mounting panel must be between 1.6 and 4.8 mm thick.
(3) Secure the mounting brackets with a uniform tightening torque of 0.5 to
0.6 N·m. Use a panel that is clean, undistorted, and strong enough to ad-
equately support the Removable Box.
(4) Do not use the Removable Box in a location that is subject to water or oil.
1. Refer to the cutout dimensions in the following diagram and cut out a hole
for embedding the Removable Box, Then insert the Removable Box from
the front side of the panel.
+0.5
95
95
0
+0.5
+0.
61.5
61.5
0
Section 4-4