Omron NS - HOST Connection Manual page 55

Ns-series programmable terminals
Table of Contents

Advertisement

SM
PT memory ($W) change notice
When PT memory $W changed as a result of PT operation and when this $W address
is higher than the address designated with Notice start $W in the communications
settings menu, this command is sent from PT to host.
Response from host to PT is not needed.
When sent from host to PT, illegal command error occurs.
Command format
ESC
command
$1B
S
[Settings]
*A
*L
*D
SB
PT memory ($B) change notice
When PT memory $B changed as a result of PT operation and when this $B address is
higher than the address designated with Notice start $B in the communications
settings menu, this command is sent from PT to host.
Response from host to PT is not needed.
When sent from host to PT, illegal command error occurs.
Command format
ESC
command
$1B
S
[Settings]
18
*A
M
0000 to 7FFF
Changed address number (hexadecimal 4 digits)
01 to 50
Number of changed words (BCD 2 digits)
0000 to FFFF
Word data (zero suppressed hexadecimal 1 to 4 digits)
","
Divide multiple word data by comma [,] ($2C).
Data ending with comma cause error.
*A
B
*L
*D
Variable
length
*B
*D
SUM
0
1
SUM
CR
$0D
CR
$0D

Advertisement

Table of Contents
loading

Table of Contents