Omron NS - HOST Connection Manual page 37

Ns-series programmable terminals
Table of Contents

Advertisement

Device setting errors are not likely to occur. This because, setting is done using the method
by which a selection is made from a list of accessible addresses for each temperature
controller model.
However, in below cases in which the address is not selected from the list of accessible
addresses an invalid address may have been assigned. In such a case, a device setting
error may occur.
!
!
!
Furthermore,
!
Writing to read-only area
!
Writing while communications writing was prohibited
cause device setting errors to occur.
2-7-3 Communications address set when functional part was copied
using repeat command
In NS-Designer, you can select functional object and when you then execute 'repeat' , you
can copy while communications addresses are being added.
The temperature controller's address is a double word address. To increment a double word
address by 1, you need to increment a single word address by 2.
Address in NS-Designer is expressed as a 1 word address. When repeat command is used
to copy functional object, 1 word is added to 1 word address.
For that reason, when communications address offset width is 1 while repeat command is
used, part with the same communications address is copied twice.
For that reason, set always offset in multiples of 2 to specify communications
address with single word access.
Communications address set when functional object was copied using
repeat command when index was assigned.
Communications address set by 'Allocate Addresses Automatically ' in the
frame property.
Communications address set by using the macro function.
Actual address
Internal address
Double word
Single word
+0
+0
+0
(0.5)
+1
+1
+2
+1
(1.5)
+3
Address originally set for functional
object
Omit figures below decimal0.5->0
Omit figures below decimal 0.5->0
25