Specifications Ratings - Omron H5CX-N Datasheet

Digital timer
Table of Contents

Advertisement

Digital Timer H5CX-B@-N
• H5CX Digital Timers with 6-digit Display, 2-stage Setting,
and Forecast Output (DIN 48 x 48-mm)
• Times the daily operating hours of machinery and tools,
predicting and notifying when maintenance is required.
• Easy-to-read backlit negative LCD with 6 digits (displays
to 99999.9 h).
• The 2-stage settings and forecast output are ideal for
maintenance applications.
Specifications
Ratings
Classification
Power supply voltage
Operating voltage
Ratings
fluctuation range
Power consumption
Mounting method
External connections
Degree of protection
Digits
Time range
Timer mode
Input signals
Inputs
Input method
Signal, reset, gate
Reset system
Power reset
Reset voltage
Sensor waiting time
Output modes
Outputs
Output type
Display
Memory backup
Operating temperature range
Storage temperature range
Operating humidity range
Case color
Attachments
*1. Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)
Voltage
Applied voltage
12 to 24 VDC
26.4 VDC
*2. The display is lit only when the power is ON.
Digital Timer with 6-digit display, 2-stage setting, and forecast output
12 to 24 VDC
90% to 110% rated supply voltage
*1
Approx. 2.3 W
Flush mounting
Screw terminals
IEC IP66, UL508 Type 4X (indoors) for panel front surface only and only when Y92S-29 Waterproof Packing is used
6 digits
0.01 s to 9999.99 s, 1 s to 99 h 59 min 59 s, 0.1 min to 99999.9 min, 0.1 h to 99999.9 h
Elapsed time (Up)
Signal, reset, gate
No-voltage Input
ON impedance
ON residual voltage : 3 V max.
OFF impedance
Voltage Input
High (logic) level
Low (logic) level
No-voltage (NPN) input/voltage (PNP) input (switchable)
Minimum input signal width: 1 or 20 ms (selectable, same for all input)
Power resets (only for A mode), external and manual reset
Minimum power-opening time: 0.5 s (except for F-1 mode)
10% max. of rated supply voltage
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
A, F-1
Transistor output: NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V)
Leakage current: 0.1 mA max.
7-segment, negative transmissive LCD;
Present value: 10-mm-high characters, red
Set value: 6-mm-high characters, green
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
-10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
-25 to 70°C (with no icing or condensation)
25 to 85%
Black (N1.5)
Waterproof packing, flush mounting adapter, unit label
Inrush current (peak value)
4.4 A
: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)
: 100 kΩ min.
: 4.5 to 30 VDC
: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
*2
Time
1.7 ms
H5CX-B@-N
33

Advertisement

Table of Contents
loading