Omron E5 R Selection Manual page 46

Digital controllers
Hide thumbs Also See for E5 R:
Table of Contents

Advertisement

less than
1 second
Expansion control setting level
l.exc
less than
1 second
CH
p-on
P-ON: Operation at power ON
CONT/STOP/MANU
cont
M
CH
sptr
SPTR: SP tracking
OFF/ON
off
M
CH
pidi
SPID: SPID set automatic
selection data
pV
PV/DV
M
CH
PIDH:
M
pidh
PID set automatic selection
0. 50
hysteresis
M
0.10 to 99.99
CH
p-db
P-DB: PV dead band
0
0 to 99999
M
CJC.1: Input 1
cjc.1
Cold junction compensation
on
OFF/ON
CJC.4: Input 4
cjc.4
Cold junction
on
compensation
OFF/ON
M
CH
alfa
ALFA:
0.00 to 1.00
0. 65
M
CH
pVtr
PVTR: PV tracking
OFF/ON
off
M
CH
mant
MANT: Manual output method
HOLD/INIT
hold
M
MANI:
CH
mani
Manual MV initial value
5.0 to 105.0 (standard control)
0. 0
(See note 1.)
M
CH
ORLM:
orlm
MV change rate limit mode
0
Mode 0:0/Mode 1:1
M
CH
at-g
AT-G: AT calculated gain
0.1 to 10.0
1. 0
M
CH
at-h
AT-H: AT hysteresis
0.1 to 9.9
0. 2
M
CH
LCMA:
lcma
Limit cycle MV amplitude
20. 0
5.0 to 50.0
M
CH
TATE:
tate
Tentative AT execute judgment
10. 0
deviation
0.0 to 100.0
M
CH
RBMP: Bumpless at Run Disable: OFF/
rbmp
Enable: ON
off
M
CH
PMEC:
pmec
Operation at potentiometer
off
input error
Stop: OFF/Continue: ON
M
CH
DOST:
dost
Disturbance overshoot
off
adjustment function
OFF/ON
Note: Heating/cooling control: 105.0 to 105.0.
46
Digital Controllers
Advanced function setting level
l. adf
INIT:
init
Parameter initialization
off
OFF/ON
M
PF1: PF1 setting
pf1
OFF/RUN/STOP/R-S/ALLR/
a-m
ALLS/AT/BANK/A-M/PFDP
M
PF2: PF2 setting
pf2
OFF/RUN/STOP/R-S/ALLR/
r-s
ALLS/AT/BANK/A-M/PFDP
M
CH
PF1.1: PF1 monitor/
pf1. 1
M
Setting item 1
1
0 to 20
M
CH
pf1.2
PF1.2: PF1 monitor/
Setting item 2
0
0 to 20
CH
PF1.5: PF1 monitor/
pf1.5
Setting item 5
0
0 to 20
M
CH
PF2.1: PF2 monitor/
pf2. 1
Setting item 1
1
10 to 20
M
CH
PF2.2: PF2 monitor/
pf2.2
Setting item 2
0
0 to 20
CH
PF2.5: PF2 monitor/
pf2.5
Setting item 5
0
0 to 20
M
ch-n
CH-N: Number of
enabled channels
M
ramm
RAMM: RAM write mode
BKUP/RAM
bkup
M
cmoV
CMOV:
Move to calibration level
0
1999 to 9999
E5AR/E5ER
Entered from operation adjustment area.
1 s min.
Input initial setting level
l. 0
i1-t
I1-T: Input 1 input type
2
0 to 19
M
I1DU:
i1du
Input 1 temperature units
c
C/ F
M
i2-t
I2-T: Input 2 input type
0 to 19
2
M
I2DU:
i2du
Input 2 temperature units
c
C/ F
M
M
i3-t
I3-T: Input 3 input type
0 to 19
2
M
I3DU:
i3du
Input 3 temperature units
c
C/ F
M
i4-t
I4-T: Input 4 input type
0 to 19
0
M
I4DU:
i4du
Input 4 temperature units
c
C/ F
M
CH
INP.1:
inp.1
Scaling input value 1
4. 000
M
DSP.1:
CH
dsp.1
Scaling display value 1
0
19999 to Scaling display
M
value 2-1
CH
inp.2
INP.2:
Scaling input value 2
20. 000
M
CH
DSP.2:
dsp.2
Scaling display value 2
0
+1 to 99999
M
CH
dp
DP: Decimal point position
0 to 4
0
M
RSPH:
CH
rsph
Remote SP upper limit
Lower limit of sensor setting range to
1300. 0
upper limit of sensor setting range
M
RSPL:
CH
rspl
Remote SP lower limit
Lower limit of sensor setting range to
-200. 0
upper limit of sensor setting range
M
CH
pVdp
PVDP: PV decimal point display
OFF/ON
on
M
SNC: Sensor induction
snc
noise reduction
50hz
50 Hz/60 Hz
M
AMOV:
amoV
Move to advanced function setting level
0
1999 to 9999
Password: -169
1
*
Temperature: SP lower limit
*
2
Temperature: Lower limit of sensor setting
3
*
1/4 input Standard (0)/heating or cooling (1)
2 input
less than
1 second
Control initial setting level
l. 1
01-T: Output 1 type
o1-t
Pulse voltage output (0)/
1
Linear current output (1)
M
03-T: Output 3 type
o3-t
Pulse voltage output (0)/
Linear current output (1)
1
M
CO1-T:
co1-t
Linear current output 1 type
1
0 to 20 mA (0)//4 to 20 mA (1)
M
CO2-T:
co2-t
Linear current output 2 type
1
0 to 20 mA (0)//4 to 20 mA (1)
M
CO3-T:
co3-t
Linear current output 3 type
0 to 20 mA (0)//4 to 20 mA (1)
1
M
CO4-T:
co4-t
Linear current output 4 type
M
0 to 20 mA (0)//4 to 20 mA (1)
1
M
CH
SL-H: SP upper limit*
1
sl-h
1300. 0
M
CH
SL-L: SP lower limit*
2
sl-l
-200. 0
M
mode
MODE: Control mode*
3
0
M
CH
OREV: Forward/reverse operation
oreV
Reverse (heating): OR-R/
or-r
Forward (cooling): OR-D
M
CH
CLFL: Closed/Floating
clfl
Floating: FLOAT/
float
Closed: CLOSE
+1 to upper limit of sensor setting range
Analog: SP lower limit + 1 to 99,999 or display
value corresponding to input upper limit,
whichever is smaller
display value 2
range to SP upper limit 1
Analog:
1,999 or display value corresponding to
input lower limit
Standard (0)/heating or cooling (1)
Standard with remote SP (2)/
Heating or cooling (3) with remote SP/
Proportion (4)/Cascade standard (5)/
Cascade heating or cooling (6)
less than
1 second