Omron D4E-N Datasheet page 4

Small sealed switch
Table of Contents

Advertisement

■ Ratings
Rated voltage
Resistive load
NC
125 VAC
5 (1) A
250 VAC
5 (1) A
8 VDC
5 (1) A
14 VDC
5 (1) A
30 VDC
5 (1) A
125 VDC
0.5 A
250 VDC
0.25 A
Inrush current
NC
NO
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
■ Characteristics
Degree of protection
Durability (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (Ui)
Switching overvoltage
Pollution degree
(operating environment)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC269 approved)
Conditional short-circuit current
Conventional enclosed thermal current
(I
)
the
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. Durability values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
F-34
Small Sealed Switch
General-purpose
Non-inductive load
Lamp load
NO
NC
NO
1.5 (1) A
1.5 (1) A
---
---
---
---
---
10 A max.
10 A max.
IP67
Mechanical: 10,000,000 operations min.
Electrical:
500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
0.1 mm to 0.5 m/sec
Mechanical: 120 operations/min
Electrical:
30 operations/min
50/60 Hz
100 M min. (at 500 VDC)
15 m max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal parts
and ground, and between each terminal and non-current-carrying metal part
250 VAC
1,000 VAC max. (EN60947-5-1)
3 (EN60947-5-1)
100 A (EN60947-5-1)
5 A (EN60947-5-1)
Class II (grounding not required with double insulation)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating: –10 C to 80 C (with no icing)
Operating: 95% max.
Approx. 86 g (in case of roller plunger)
D4E-@
N
Inductive load
Inductive load
NC
NO
3 (1) A
3 (1) A
1.5 (1) A
1.5 (1) A
1.5 (1) A
0.05 A
0.03 A
2
min.
2
min.
Non-inductive load
Motor load
Resistive load
NC
NO
NC
2 (1) A
1 (1) A
0.1 A
1 A
0.5 A
---
---
0.1 A
---
0.1 A
---
0.1 A
---
---
---
---
Micro load
NO

Advertisement