Omron D4E-N Datasheet page 11

Small sealed switch
Table of Contents

Advertisement

Molded Terminal Models
■ Molded Terminal Models
The molded-terminal model is available with right-hand, left-hand and underside leads and is recommended for use where the Switch is exposed
to dust, oil or moisture. It can be used like a screw-terminal model (with a cable), and the dimensions and operating characteristics are the same
as for standard models.
(2)
Lead Supplies
Leads
V.C.T.F. S-FLEX
(vinyl cabtire coat)
Comparison between Old and New Mold Terminal Models
The D4E-N and D4E are different from each other in terminal specifi-
cations.
Location of lead output
Right-hand
D4E-@@23N
Left-hand
D4E-@@24N
Underside
---
■ Operation of Indicator-equipped Models
The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and inspection.
The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the
Switch wiring cannot be made.)
AC Operation
A neon lamp indicator is provided.
The operating voltage is 90 to 250 VAC.
Terminal protection cover
Neon lamp
(transparent)
There is no difference in operating characteristics between D4E AC
Models and corresponding D4E Standard Models.
There is no difference in dimensions between D4E AC Models and
D4E Standard Models.
Example:
Basic type: D4E-1A23N
When placing your order for the molded terminal model with an neon
lamp operation indicator, specify the model number as D4E-1A23LN.
(1)
Nominal
Finished outside diameter
cross-sectional area
2
3 conductors
0.75 mm
7 mm dia.
D4E-N
D4E
D4E-@@21
D4E-@@23
D4E-@@22
Example:
Standard type:
D4E-1A20N
Location of lead output: Right-hand
Suffix by Location of Lead Outlet
Location of lead output
(1) Right-hand
(2) Left-hand
Terminal connections
Black: COM
White: NO
Red:
NC
Internal Circuit
Power supply
Built-in switch
Neon lamp R = 240 kΩ
Small Sealed Switch
D4E-1A23N
Suffix for pre-wired terminal
COM, NC, NO
D4E-@@23N
D4E-@@24N
Standard length
3 m
Load
D4E-@
N
F-41