Output Unit Specifications; Contact Output Units - Omron CQM1H - 08-2005 Operation Manual

Programmable controllers; inner boards
Hide thumbs Also See for CQM1H - 08-2005:
Table of Contents

Advertisement

Output Unit Specifications

2-3
Output Unit Specifications
2-3-1

Contact Output Units

Item
Name
8-point Contact Output Unit
Max. Switching
2 A, 250 V AC (cosφ= 1)
Capacity
2 A, 250 V AC (cosφ= 0.4)
2 A, 24 V DC (16 A/Unit)
Min. Switching
10 mA, 5 V DC
Capacity
Relay
G6D-1A
Service Life of
Electrical: 300,000 operations (resistive load)
Relay
100,000 operations (inductive load)
Mechanical: 20,000,000 operations
(See note.)
ON Delay
10 ms max.
OFF Delay
5 ms max.
No. of Outputs
8 points (independent commons)
Internal Current
430 mA max. at 5 V DC
Consumption
Weight
200 grams max.
Circuit
Configuration
Internal
Circuits
Internal
Circuits
Terminal
Connections
CQM1-OC221
Output
LED
OUT0
COM0
Maximum
250 V AC: 2 A
Output
24 V DC: 2 A
LED
OUT7
COM7
OUT0
B0
COM0
A0
OUT1
B1
COM1
A1
OUT2
B2
COM2
A2
OUT3
B3
COM3
A3
OUT4
B4
COM4
A4
OUT5
B5
COM5
A5
OUT6
B6
COM6
A6
OUT7
B7
COM7
A7
NC
B8
NC
A8
Note The values for relay service life in the above table represent the minimum val-
ues. The following chart gives reference values for the actual service life.
CQM1-OC222
16-point Contact Output Unit
2 A, 250 V AC (cosφ= 1)
2 A, 250 V AC (cosφ= 0.4)
2 A, 24 V DC (8 A/Unit)
10 mA, 5 V DC
G6D-1A
Electrical: 300,000 operations (resistive load)
100,000 operations (inductive load)
Mechanical: 20,000,000 operations
(See note.)
10 ms max.
5 ms max.
16 points (16 points/common, 1 circuit))
850 mA max. at 5 V DC
230 grams max.
Output
LED
Internal
Circuits
OUT0
OUT1
A0
OUT2
OUT3
A1
OUT4
OUT5
A2
OUT6
OUT7
A3
OUT8
OUT9
A4
OUT10
OUT11
A5
OUT12
OUT13
A6
OUT14
OUT15
A7
COM
COM
A8
Section 2-3
OUT0
OUT15
COM
Maximum
250 V AC: 2 A
24 V DC: 2 A
B0
B1
B2
B3
B4
B5
B6
B7
B8
59

Hide quick links: