Introduction

4-1

Introduction

4-1-1 Overview

CPM1/CPM1A
Communications
CPM2A/CPM2C
Communications
SRM1(-V2) Communications The following types of communications can be executed through the ports of the

4-1-2 Wiring Ports

226
The CPM1/CPM1A can execute a variety of communications through its periph-
eral port via an RS-232C Adapter or an RS-422 Adapter.
Host Link Communications
The CPM1/CPM1A PCs are compatible with the Host Link System, which allows
up to 32 PCs to be controlled from a host computer. An RS-232C Adapter is used
for 1:1 communications and an RS-422 Adapter and B500-AL004 Link Adapter
are used for 1:N communications.
A CPM1/CPM1A equipped with an RS-232C Adapter can also communicate
with a OMRON Programmable Terminal using host link commands.
Refer to 4-2-1 CPM1/CPM1A Host Link Communications in this manual and
1-2-2 Host Link Communications in the CPM1 Operation Manual or 1-2-2 Host
Link Communications in the CPM1A Operation Manual for more details.
One-to-one PC Link
A data link can be created with a data area in another CPM1, CPM1A, CPM2A,
CPM2C, CQM1, C200HX/HG/HE, or C200HS PC. An RS-232C Adapter is used
to make the 1:1 connection.
Refer to 4-2-3 CPM1/CPM1A 1:1 PC Link Communications in this manual and
1-2-3 One-to-one PC Communications Links in the CPM1 Operation Manual or
1-2-3 One-to-one PC Communications Links in the CPM1A Operation Manual
for more details.
One-to-one NT Link
Using the 1:1 NT Link, the CPM1/CPM1A PC can connected to the OMRON
Programmable Terminal (NT Link Interface) through an RS-232C Adapter.
Refer to 4-2-2 CPM1/CPM1A 1:1 NT Link Communications in this manual and
1-2-4 One-to-one NT Link Communications in the CPM1 Operation Manual or
NT Link Communications in the CPM1A Operation Manual for more details.
The following types of communications can be executed through the ports of the
CPM2A/CPM2C.
Host Link communications with a host computer
RS-232C communications with a computer or other device
One-to-one PC Link communications with another PC
One-to-one NT Link communications with OMRON Programmable Terminals
This section explains the required PC Setup and methods for using these types
of communications.
SRM1(-V2).
Host Link communications with a host computer
RS-232C communications with a computer or other device
One-to-one PC Link communications with another PC
One-to-one NT Link communications with OMRON Programmable Terminals
Note One-to-one NT Link communications are not possible with the SRM1-C01,
which is equipped with only a peripheral port. The SRM1-C01 may be connected
to a PT through an RS-232C Adapter in Host Link mode.
Refer to the CPM1 Operation Manual, CPM1A Operation Manual, CPM2A Op-
eration Manual, CPM2C Operation Manual, or SRM1 Master Control Units Op-
eration Manual for information on wiring the communications ports.