If A Problem Occurs; Troubleshooting - Sennheiser EW 300 IEM G3 Instruction Manual

Hide thumbs Also See for EW 300 IEM G3:
Table of Contents

Advertisement

If a problem occurs ...

SR 300 IEM G3 transmitter
Problem
Possible cause
Transmitter cannot be
Lock mode is activated
operated, "Locked"
appears on the display
panel
No operation indication No mains connection
No RF signal at the
Transmitter and receiver are not
receiver
on the same channel
If
on the transmitter display:
RF signal is deactivated
Very weak RF signal at
Transmission range is exceeded
the receiver
RF signal available,
No input signal at the transmitter Check the audio level on the transmitter display
no audio signal at the
receiver
Very low input signal
Audio signal has a high
Transmitter sensitivity is adjusted
level of background
too low
noise
Audio signal is
If
distorted
on the transmitter display:
transmitter sensitivity is adjusted
too high
Receiver's audio output level is
adjusted too high
"RF
Mute" additionally appears
"AF
PEAK" additionally appears
Possible solution
Deactivate the lock mode (see page 18 and page 24).
Check the connections of the mains unit.
Synchronize the transmitter with the receiver
(see page 20).
Activate the RF signal of the transmitter (see page 19).
Reduce the distance between receiver and transmitter.
Reposition the antennas.
Increase the transmission power (see page 24).
Reduce the squelch threshold (see table on page 20).
(see page 6).
Check the audio level on the transmitter display
(see page 6), increase the level of the input signal
or adjust the input sensitivity (see page 24).
Adjust the transmitter sensitivity correctly (see page 24).
Adjust the transmitter sensitivity correctly (see page 24).
Reduce the receiver's audio output level.
If a problem occurs ...
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

300 iem seriesEk 300 iem g3

Table of Contents