Sensitivity Adjustment - Sony SUPER MOTION HDC-P43 Service Manual

Multi purpose camera
Hide thumbs Also See for SUPER MOTION HDC-P43:
Table of Contents

Advertisement

6.
Make setting to the values adjusted in step 3 and step 4, store the file every following format.
Format
MSU:
[CONFIG] button → ON (lit)
• When using the HDCU4300
Touch panel operation: [Multi Format] → [Base Format] → [4K/HFR Format]
- 4K/59.94P (2×): unsupported
- HD/59.94P (2×):
→ "1920x1080/59.94P(x2)"
- HD/59.94P (4×):
→ "1920x1080/59.94P(x4)"
- HD/59.94P (8×):
→ "1920x1080/59.94P(x8)"
• When using the BPU4000/BPU4500
Touch panel operation: [BPU Multi Format] → [Shooting Transmit]
- 4K/59.94P (2×):
→ "4096x2160/59.94P(x2)"
- HD/59.94P (2×):
→ "1920x1080/59.94P(x2)"
- HD/59.94P (4×):
→ "1920x1080/59.94P(x4)"
- HD/59.94P (8×):
→ "1920x1080/59.94P(x8)"
File store
MENU: SERVICE
PAGE: BLACK SHADING
ITEM: STORE FILE
5-3-2.

Sensitivity Adjustment

Equipment: Waveform monitor (R, G, B)
Test point: SLOT1 connectors (BNC x4) on the HDCU4300 or BPU4000/4500
Object: Grayscale chart
Preparations
• Setting for the MSU
CLOSE button → OFF (dark)
GAMMA OFF button → OFF (lit)
MASTER GAIN → 0 (0 dB)
DETAIL OFF button → OFF (lit)
Touch panel operation: (Page 1) → [Detail] → [1/3] → Level Dep OFF → OFF
• Confirm the amplitude of TEST SAW waveform.
1.
Press the TEST 1 button of MSU to output TEST SAW waveform and to turn ON (lit).
2.
Confirm that the amplitude is 700 mV using the waveform monitor.
3.
If the amplitude is not 700 mV, confirm that R, G and B values are "0" by camera setup menu.
MENU: PAINT
PAGE: VIDEO LEVEL
ITEM: WHITE [R], [G], [B]
4.
Press the TEST 1 button of MSU to stop TEST SAW waveform output and to turn OFF (unlit).
• Shoot the grayscale chart so that it is aligned with the under scanned monitor frame.
HDC-P43