2. Use the Display disk configuration option on
the Work with Disk Configuration display
under Work with Disk Units to display the
system disk configuration status (see
Figure 3-3 on page 3-31).
Display Disk Configuration Status
Serial
ASP
Unit
Number
Type
Model
Address
Status
I
Mirrored
I
610Z 0015
OOIO-OIOOFFFF
Active
·C
10-IZ345_
- - -
10-IZ347
610Z 0815
0010-0300FFFF
Active
-2;
18·IZ346- 610Z 0015
8018-0Z00FFFF
Suspended_
.
18.IZ348= 610Z 8015
8010-0400FFFF
Active
.Z.
- - -
- - -
-
- -
- - -
-
- -
- - -
-
- -
- - -
-
- -
- - - -
- -
- - -
-
- -
- - - -
- -
- - -
-
- -
More •••
Press Enter to continue.
F3=Exit
F5=Refresh
F11=OispllliY non-configured units
F12"Cancel
Figure
3-3.
Display Disk Configuration Status
Suspend Missing Disk Units (One
Missing Disk Unit):
If you see the display
shown in Figure 3-4 (showing one missing disk
unit), perform the following:
1. Use the Display disk configuration option on
the Work with Disk Configuration display
under Work with Disk Units to display the
system disk configuration status (see
Figure 3-5).
Suspend Missing Disk Units
The following disk units are missing from the system disk
configuration:
Serie'
ASP
Unit
Type
Model
Number
Address
Reference Code
I
.Z.
610Z 0015
10-IZ345_
OOIO·OIOOFFFF
0000
Press Enter to suspend missing disk units and continue the IPL.
F6=Use Dedicated Service Tool s (DST)
Fll;Oisplay unit status
More •••
Figure
3-4.
Suspend Missing Disk Units (One Missing
Disk Unit)
2. As shown in Figure 3-5, one other disk unit is
attached to the same disk I/O processor as
the missing disk unit. The missing disk unit is
causing the failure.
Display Disk Configuration Status
Status
Serial
Number
10-IZ345
10-12347-
10-23456-
10-Z3458=
Type Model
6102 0015
610Z 0015
610Z 0015
610Z OOZO
Address
OOIO-OIOOFFFF
00I0-El390FFFF
OEne-0200FFFF
00IEl-04tlElFFFF
Active
A c t i v e - - -
Suspen-ded--
Active-==
More •••
Press Enter to continue.
F3:Exit
FS:Refresh
Fl1:Display non-configured units
Fl2:Cancel
Figure
3-5.
Display Disk Configuration Status
Suspend Missing Disk Units (All
Devices on One MSIOP Failing):
If you
see the display shown in Figure 3-6 (showing all
the disk units attached to the magnetic storage I/O
processor at address 0010 failing), you cannot
determine the failing item. Perform the following:
1. Exchange the magnetic storage I/O processor.
Suspend Missing Disk Units
The
follo~ing
disk units are missing from the system disk
configuration:
Serial
ASP
Unit Type Model
Number
,
,
610Z OOZO
10-IZ345
., . . ,.
610Z OOZO
10-78454=
Address
Reference Code
OOlO-0l80FFFF
ooee
OOIO-OZOOFFFF
0000
Press Enter to suspend miSSing disk units and continue the IPL.
F6:Use Dedicated Service Tools (OST)
Fll:Oisplay unit status
More ••.
Figure
3-6. Suspend Missing Disk Units (All Devices
on One MSIOP Failing)
2. If this does not correct the problem, exchange
the disk units.
Chapter 3. Problem Isolation Procedures
3-31