vLle PIP Display Examples
Format of VLlC PIP Displays:
There are
several displays for disk unit failures that have the
format of the display shown in Figure 3-1.
Suspend Missing Disk Units
Tne following disk units are missing from the system disk
configuration:
II
II
!r;al
ASP
Unit
Type
Model
Number
I
2
6102 0915
10-12345
-1- -3-
6102 0015
10-22345-
=(
=0=
2643
0001
Hl-7654JZ1
iii
II
Address
Reference Code
0010-0109FFFF
1400
9919-9Z90FFFF
0010-FFFFFFFF
3'1"e'6
Press Enter to suspend missing disk units and continue the IPl.
F6=Use Dedicated Service Tools COST)
Fll=Display unit stll:tus
Figure
3-1.
Format of VUC PIP Displays
More •••
Type
II:
This field shows the type number of the
failing disk unit or magnetic storage
1/0
processor.
Use this field to find the correct device service
information.
Model
Ill:
This field shows the model number of
the failing disk unit or magnetic storage
1/0
processor.
Serial Number
II:
This field shows the serial
number of the failing disk unit or magnetic storage
1/0
processor.
Address
iii:
The first 4 characters in this field
are the card address of the failing magnetic
storage
1/0
processor or the magnetic storage
1/0
processor of the failing disk unit.
The sixth character from the left is the device
address of the failing disk unit.
Reference Code
II:
This field shows the unit
reference code of the failing disk unit or magnetic
storage
1/0
processor.
Find the correct unit reference code guide using
the
Type
field and follow the instructions for that
unit reference code.
3-30
ASl400 9401 Service Information
If the
Type
field contains B6xx, the problem is in
the Licensed Internal Code. Look in the "Unit Ref-
erence Code Tables" on page 2-3 under B6xx for
the unit reference code shown in the
Reference
Code
field.
In Figure 3-1, on the line where the
Unit
field con-
tains 0, the
Type
field contains 2643, and the
Ref-
erence Code
field contains 3100, use the 3100
reference code to correct the problem. The disk
unit shown above it (type 6102, serial number
10-12345, address 0010-0100, reference code
0000) is failing because of the 3100 reference
code.
If the
Unit
field contains 0 and the
Type
field con-
tains a magnetic storage
1/0
processor or
Licensed Internal Code, the
Reference Code
field
contains the cause of the failure for all disk units
shown with the same first 4 characters in the
Address
field.
Suspend Missing Disk Units (All Refer-
ence Codes
=
0000):
If you see the display
shown in Figure 3-2 (showing missing disk units
and all the reference codes are 0000), perform the
following:
1. Print or record all the disk units shown with
reference codes of 0000. For devices with
reference codes of 0000, go to ''VLlC-PIP11''
on page 3-24, step 2, and use cause code
0002. If any entries on the display have refer-
ence codes that are not 0000, use those refer-
ence codes with the device shown in the
Type
field to correct the problem.
Suspend Hissing Disk Units
The following disk units are missing from the system disk
confi gurati on:
Serial
ASP Unit Type Model
Number
Address
Reference Code
1
1
61ElZ
eelS
19-12345
aOle-eleeFFFF
oooe
: ( :2:
6102 8815
10-12346=
OOIO-0280FFFF
0000
Press Enter to suspend missing disk units and continue the IPl.
Fti"'Use Dedicated Service Tools (DST)
Fl1=Display unit status
More .•.
Figure
3-2.
Suspend Missing Disk Units (All Refer-
ence Codes = 0000)