14.1 Technical information
Oven model
Electrical connections
Required protection fuse for the oven
OVEN RATING
Ovens
Maximum electrical power
Oven grilling
Large grilling power
Small grilling power
Oven light
OVEN CAVITY DIMENSIONS
Height (cm)
Width (cm)
Depth (cm)
2
Internal volume (cm
)
14.2 The rating plate
Make sure that the voltage and capacity of the power supply line conform to the data shown on the
plate located on the oven door frame.Do not remove this plate for any reason.
Model
14.3 Electrical connection
IT IS OBLIGATORY FOR ALL ELECTRICAL EQUIPMENT TO BE EARTHED ACCORDING TO THE
METHODS LAID DOWN BY SAFETY REGULATIONS.
WHEN CONNECTING TO THE ELECTRICITY SUPPLY USING PLUG AND SOCKET, MAKE SURE
THAT BOTH ARE COMPATIBLE AND CONNECT THEM TO THE POWER SUPPLY CABLE IN
ACCORDANCE WITH THE REGULATIONS IN FORCE.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN,
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND
SOCKET ARE COMPATIBLE. DO NOT USE ANY TYPE OF ADAPTOR OR DIVERTER AS THESE
MAY CAUSE OVERHEATING OR BURNS.
WHERE A FIXED CONNECTION IS IN USE, A MULTIPOLAR CUT-OUT DEVICE MUST BE
INSTALLED ON THE SUPPLY CABLE WITH A CONTACT OPENING DISTANCE EQUAL OR
GREATER THAN 3 MM LOCATED IN A READILY REACHABLE POSITION NEAR THE
APPLIANCE.
Instructions for the installer
Serial No.
See rating plate
230 - 240 / 400-415 V 3N ~ 50 Hz
30 Amps
Electric
6.1 kW
Electric
3.0 kW (230 V)
1.8 kW (230 V)
25 W
(230 V)
Large oven
34
46
40
62560
Small oven
23
46
40
42320
49

Advertisement