12.ADAPTATION TO DIFFERENT TYPES OF GAS

BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER
SUPPLY TO THE APPLIANCE.
Appliance set for gas:
In case of operation with other types of gas, the burner nozzles must be
changed and the minimum flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
12.1 Replacing the hob nozzles
1 Remove the pan stands, and
remove all burner caps and
flame-spreader
access the burner casings.
2 Unscrew the nozzles using a 7
mm socket wrench.
3 Replace the burner nozzles
according to the type of gas to
be used (see 12.2 Burner and
nozzle characteristics table).
4 Replace the burners in the correct position.
100
Instructions for the installer
crowns
NATURAL GAS G20 (2H) 20 mbar pressure