Instructions for the installer

14.ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance from the
power supply.
The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In
case of operation with other types of gas, the burner nozzles must be changed
and the minimum flame adjusted on the gas taps. To change the nozzles,
proceed as described in the following paragraphs.
14.1 Replacing the hob nozzles
5 Extract the pan stands and remove all caps and flame-spreader crowns;
6 Unscrew the burner nozzles with a 7 mm socket spanner;
7 Replace the burner nozzles according to the type of gas to be used (see
"14.2 Burner and nozzle characteristics table").
8 Replace the burners in the correct position.
The nozzles for using city gas (G110 – 8 mbar) are available from authorised
service centres.