Combustion products
Extractor fan
Installation
5.2 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
cocks.
Replacing nozzles
1. Remove the pan supports, burner caps
and flame-spreader crowns to access
the burner cups.
2. Replace the nozzles using a 7 mm socket
wrench according to the type of gas to
be used (see the "Burner and nozzle
characteristics tables").
3. Replace the burners in their respective
housings.