Smeg CS120-7 Manual page 42

Table of Contents

Advertisement

Instructions for the installer
11.3 Gas connection
At the end of the installation, check for any leaks with a soapy solution,
never with a flame.
The tightening torque between connections that incorporate a gasket must be
between 10 and 15 Nm.
After carrying out any operation on the appliance, check that the gas
connections are properly tightened.
If the appliance is fuelled by LPG, use a standards-compliant
pressure regulator and connect to the gas cylinder in accordance with
the standards in force.
Make sure that the feed pressure complies with the values indicated
in table "12.2 Burner and nozzle characteristics table".
94