12.3 Burner and nozzle characteristics table

Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid
Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid

12.4 Final operations

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands.
Following adjustment to a gas other than the one originally set in the factory, replace the gas setting
label fixed to the appliance with the one corresponding to the new gas. The label is inserted inside the
nozzle pack (where present).
12.4.1Adjusting the hob burner minimum setting for city or natural gas
Light the burner and turn it to the minimum position.
Extract the gas tap knob and turn the adjustment screw
next to the tap rod (depending on the model) until the
correct minimum flame is achieved.
Refit the knob and verify that the burner flame is stable
(when turning the knob rapidly from the maximum to the
minimum position the flame must not go out). Repeat the
operation on all the gas taps.
12.4.2Adjusting the hob burner minimum setting for LPG
In order to adjust the minimum setting with LPG, the screw at the side of the tap rod must be tightened
clockwise all the way.
Instructions for the installer
Rated heating
capacity
(kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.0
3.5
Rated heating
capacity
(kW)
Nozzle
diameter
(1/100 mm)
1.05
1.8
3.0
3.5
LPG GAS - G30/G31 28-30/37 mbar
Reduced
capacity
(W)
50
400
65
500
85
800
94
1600
NATURAL GAS - G20 20 mbar
Prechamber
(printed on
nozzle)
72
(X)
97
(Z)
115
(Y)
133
(S)
Capacity
Capacity
(g/h G30)
(g/h G31)
76
75
131
129
218
214
255
250
Reduced capacity
(W)
400
500
800
1600
39