130 ± 6.0mVrms.
Stereo separation adjustment (SEPAH)
PREPARATION
1. Connect an R.F. signal generator to the RF antenna input.
2. Connect a scope to TPA10.
PROCEDURE
1. Select stereo mode in audio menu
2. Apply the following signal from the RF signal generator:
Video: 100 IRE flat field, 30% modulation.
Audio: 300Hz, 30% modulation, stereo (left only) (70±5dB, 75Ω OPEN, P/S 10dB).
NOTE
After setting 30% modulation with P.L. SW and N.R. SW OFF, turn P.L. SW and N.R.
SW ON.
3. In service mode, adjust the MTS Low-Level separation adjustment "SEPAL" data until the
amplitude displayed on the scope is minimum.
4. Apply the following signal from the RF signal generator:
Video: 100 IRE flat field, 30% modulation
Audio: 3KHz, 30% modulation, stereo (left only) (70 ±5dB, 75Ω OPEN, P/S 10dB).
NOTE
After setting 30% modulation with P.L. SW and N.R. SW OFF, turn P.L. SW and N.R.
SW ON.
5. Adjust the MTS High-level separation adjustment "SEPAH" until the amplitude displayed on the
scope is minimum.
http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s1406000000.html (2 of 3)05.12.2008 0:03:31