WARNING
The potential source of x ray radiation in the TV set is in the high voltage section and the picture tube.
NOTE
It is important to use an accurate, calibrated high voltage meter.
Set the brightness, picture, sharpness and color controls to minimum.
Measure the high voltage. The high voltage should be 33.0 ± 1.0kV. If the upper limit is out of
tolerance, immediate service and correction is required to insure safe operation and to prevent the
possibility of prematurecomponent failure.
Horizontal oscillator disable circuit test
This test must be performed as a final check before the receiver is returned to the customer. See
horizontal oscillator disable circuit procedure check in this manual.