6. Note the original locations and mounting of the degaussing coil and the dag ground assembly to
insure proper reinstallation on the replacement CRT.
To remove and remount the degaussing coil:
Unhook the coil spring from the bottom corners of the CRT ears.
Release the braid loop from the upper corners of the CRT ears.
7. Mount the dag ground braid on the replacement CRT. Position the degaussing coil with new ties.
Dress coil as was on the original CRT.
8. Replace the components on CRT neck and reinstall into cabinet. Verify that all ground wires and
circuit board plugs get connected.
NOTE
Reuse all the clampers and mounting brackets from the degauss coil and screen, and when
remounting the degauss coil assure that is not touching the speakers, this can be done by placing
some tape, this may cause mask vibration. The mounting brackets andclampers are not supplied
with the replacements.
IMPORTANT NOTICE
When ordering the CRT, please order CRT and CRT kit also. Please see parts list section for part
numbers.
TOP PREVIOUS NEXT
http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s1001000000.html (2 of 2)05.12.2008 0:01:40