http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s0201000000.html
1. Connect the short jumper between TPD16 & TPD17.
2. Connect the jumper diode between TPD14 and TPD15 (anode connected to TPD15 and cathode
to TPD14).
3. Apply 75VAC to AC input of isolation transformer.
4. Turn the receiver on.
5. Apply a monoscope pattern.
6. Set customer picture and brightness controls to the minimum.
7. tSet current within 50μA to 100μA by changing the picture and bright controls.
8. Slowly increase AC voltage at the input of the isolation transformer and confirm HHS voltage
measure
36kV
9. Turn power off and remove jigs.
TOP PREVIOUS NEXT