3. Using a 11/16" nutdriver, attach the four nuts (two for each lead) securing the heavy leads to the
terminals on contactor CR1. See Wiring Diagram.
4. Connect the leads 633 and 634 to the quick connects of contactor CR1. See Wiring Diagram.
5. Using a 5/16" nutdriver, attach the thirteen screws securing the CV box support to the CV box base.
6. Using a 9/16" open-end wrench and a 9/16" nutdriver, attach the nut, bolt, lock washer and three
flat washers securing each side of the CV box to the fuel tank rail (two sets). See Wiring Diagram
7.
Perform the
Case Cover Replacement
8. Perform the Retest After Repair Procedure.
Procedure.
Figure F.40 – CV box mounting hardware location