Comelit Logos Technical Manual
Hide thumbs Also See for Logos:

Advertisement

Quick Links

Logos
LS9431V
F U L L T E C H N I C A L M A N U A L
Join us
in taking care
of our planet

Advertisement

Table of Contents
loading

Summary of Contents for Comelit Logos

  • Page 1 Logos LS9431V F U L L T E C H N I C A L M A N U A L Join us in taking care of our planet...
  • Page 2 Simplebus 2 system Single-family kit consisting of Quadra series entrance panel art. 4893M and Logos series hands-free door entry monitor art. LS8731, Simplebus 2 system. The entrance panel has call buttons to expand the kit for up to 4 residences.
  • Page 3 | Table of contents | Table of contents Kit art. LS9431V Notes for the installer Art. 4893M Description Technical specifications Installation Programming Art. 1209 Description Technical specifications Art. LS8731 Description Technical specifications Programming the user code Installation Programming the door entry monitor Operating distances Wiring diagrams System expansion diagrams...
  • Page 4 | Table of contents | Kit art. LS9431V The kit components are supplied pre-programmed to work as a single-family setup. LS8731 LS9431V 1209 4893M 1214/2C 1216 The door entry monitor has an NFC connection which means it can be programmed quickly and easily via the MyComelit app, available to download free of charge.
  • Page 5 | Table of contents | Notes for the installer 72° 72° 72° 50 cm 50 cm 50 cm 92 cm 85° The camera must not be installed in front of light sources, or in places where the filmed subject is against the light.
  • Page 6 | Table of contents | Art. 4893M Description Wall-mounted external unit for Quadra series door entry monitor. Die-cast aluminium front panel, wide-angle colour video camera and single LED for lighting at night. Mechanical buttons with the option of setting 1 to 4 call buttons via DIP-switch.
  • Page 7 | Table of contents | 8. DIP-SWITCH for function programming. 9. PR programming input/output switch. CNF programming confirmation switch. 10. Terminal block M1: LL bus line connection. RTE request to exit button input. COM common input for RTE and DO contacts. DO door open indication input.
  • Page 8: Technical Specifications

    | Table of contents | Technical specifications GENERAL DATA Type Complete unit Height (mm) 195 Width (mm) 95 Depth (mm) 28 Product weight (g) 300 Product colour Grey RAL 9006, Black RAL9005 Surface mounting Yes COMPATIBLE SYSTEMS Simplebus 2 audio/video kit with power supply unit art.
  • Page 9: Installation

    | Table of contents | Installation OPEN You can download the free software (art. 1235A) to print the entrance panel name cards, using the adhesive pre-cut sheets available in our catalogue (art. 1217A).
  • Page 10 | Table of contents | Before securing the screw, make sure that you do not need to program the external unit and make sure that the metal front panel does not rub against other metal parts, with consequent risk of damage to its insulating coating. While the system is running, take care not to accidentally call users when replacing the nameplate labels.
  • Page 11: Changing Nameplates

    | Table of contents | CHANGING NAMEPLATES...
  • Page 12 | Table of contents | Programming ENTRANCE PANEL SETTINGS f Permanently set the S1 DIP-switches corresponding to the function you want to program in accordance with the table below (you do not need to enter programming mode) FUNCTION The SE output and the C-NO relay are controlled by 2 separate buttons on the door entry monitor: the key button (SE) and the generic actuator button (C-NO) 1 2 3 4...
  • Page 13 | Table of contents | PROGRAMMING CALL CODES FOR TWO-FAMILY AND FOUR-FAMILY VERSION f Take note of the DIP-switch settings. f Set the code corresponding to the desired programming. 1 2 3 4 default 1 2 3 4 1 2 3 4...
  • Page 14 | Table of contents | f Reset the DIP-switch settings.
  • Page 15 | Table of contents | PROGRAMMING AN ADDITIONAL ENTRANCE PANEL With switching device art. 1405, only one additional entrance panel may be installed. The two entrance panels must be programmed as main and secondary ; see table below. • The “Main entrance panel” carries out lock-release (or actuator) commands only when it is in call or self activation status.
  • Page 16 | Table of contents | f Reset the DIP-switch settings.
  • Page 17: Programming A Generic Call Address

    | Table of contents | PROGRAMMING A GENERIC CALL ADDRESS f Take note of the DIP-switch settings. f Set the call code of the apartment you wish to call (see Table of user codes) example code 2 1 2 3 4...
  • Page 18: Restore Default

    | Table of contents | RESTORE DEFAULT f Take note of the DIP-switch settings. f Set the DIP-switches to position 254 (ON 2, 3, 4, 5, 6, 7, 8) 1 2 3 4 f Reset the DIP-switch settings.
  • Page 19 | Table of contents | Art. 1209 Description 33 VDC power supply unit for Simplebus 2 KIT, for direct connection to the external unit and internal unit. Equipped with overload and short circuit protection. Input voltage 110-240 VAC. Dimensions: 106 x 62 x 89 mm (6 DIN modules).
  • Page 20: Main Features

    | Table of contents | Technical specifications MAIN FEATURES Power supply voltage 110-240 VAC Max. current delivered (A) Applicable to DIN rail Number of DIN modules GENERAL DATA Height (mm) Width (mm) Depth (mm) Coating material type Plastic Product colour White Operating temperature (°C) -5 to 40...
  • Page 21 Art. LS8731 Description Logos series hands-free, surface-mounted door entry monitor with 5-inch colour display. Simplebus 2 system. It has backlit buttons for the audio and to end communication as well as 4 programmable mechanical buttons, which are pre-configured to trigger the actions that the user uses most: electric lock, memovideo, control of an actuator, and self activation.
  • Page 22 | Table of contents | 7. Speaker. 8. Dip-switch for programming the user code. 9. CV5 Jumper for video closure. 10. Pin for securing the terminal block.
  • Page 23 | Table of contents | FRONT BUTTONS - FACTORY PROGRAMMING Video memo f Press the button to view the recorded video. Generic actuator f Press the button to activate a generic actuator (art. 1256) or the relay for the external entrance panel.
  • Page 24: Side Buttons

    | Table of contents | SIDE BUTTONS Button for activating “Silent mode” Confirm button Menu access and navigation button Buttons for scrolling menus and selecting values ACTIVATING “SILENT MODE” f Press to activate/deactivate Silent mode. » The red LED indicates that the function is active. ACCESSING AND NAVIGATING MENUS f Press one of the following buttons to access the user menu.
  • Page 25 | Table of contents | User menu options Select this menu to exit the user menu and scan the QR code to EX I T access the online documentation. Select this menu to access the log of recordings and to view them (up VI D E O M E M O to 30 video memos can be stored).
  • Page 26 | Table of contents | √ The function must be authorised by the installer using the MyComelit app or via the installer menu on the door entry monitor. MODE Select this menu to configure the function activation and the PROGRAMMING operating time band MANUAL •...
  • Page 27: Indicator Led

    | Table of contents | INDICATOR LED Red LED Flashing: communication taking place. Flashing: incoming call/communication taking place. Flashing with door entry monitor in standby: “Door open” indication. White LED Lit steadily with door entry monitor in standby: “Auto lock-release on receipt of call”...
  • Page 28 | Table of contents | Technical specifications 135 mm 23 mm GENERAL DATA Product weight 430 grams Product colour White RAL9003, Black RAL9005 Coating material type ABS, PMMA Surface mounting Yes Desk base mounting Yes, with specific accessory COMPATIBLE SYSTEMS Simplebus 2 audio/video with power supply unit art.
  • Page 29: General Features

    | Table of contents | SETTINGS Loudspeaker volume Yes Ringtone volume Yes Screen brightness Yes Screen contrast Yes Screen colour Yes NETWORK AND COMMUNICATION PROTOCOL User function programming via OSD menu Installer function programming via OSD menu Function programming via NFC and MyComelit app ENVIRONMENTAL AND CONFORMITY SPECIFICATIONS IP protection rating IP30...
  • Page 30 √ All dip-switches must be set to OFF (factory programming) and should remain OFF even during normal operation. OFF ! 1. Open the MyComelit app and log in (or create a new account if it is the first time you have accessed it). 2. Select "LOGOS DOOR ENTRY MONITORS SETUP".
  • Page 31 | Table of contents | 3. Enter the desired user code and press “WRITE”. User code User code MyComelit user code user code user code WRITE WRITE Bring your smartphone close to the door entry monitor 4. Bring your smartphone close to the NFC detection area of the door entry monitor (identified by its label) and make a circular motion until you feel it vibrate.
  • Page 32 | Table of contents | if you want to program the user codes for other door entry monitors in sequence: 5.B Press "CONTINUE". Configuration complete! CONTINUE CONTINUE 6.B Select the desired increment interval. MyComelit MyComelit user code user code Select an increment 7.B Bring your smartphone close to the NFC detection area of the new door entry monitor (identified by its label) and make a circular motion until you feel it vibrate.
  • Page 33 | Table of contents | PROGRAMMING THE USER CODE USING THE DIP-SWITCHES f Set the DIP-switches to ON to program a user code on the door entry monitor, as per Table of user codes. Example: code 4.
  • Page 34 | Table of contents | Installation Fixing points for use when installing in compatible boxes CLACK...
  • Page 35 | Table of contents | DISASSEMBLING THE DOOR ENTRY MONITOR REMOVING AND FITTING THE CONNECTION TERMINALS CLACK...
  • Page 36 | Table of contents | Programming the door entry monitor The programming can be customised: • Using the MyComelit app via a smartphone • Using the installer menu on the door entry monitor << OR >> VIA MYCOMELIT APP VIA DOOR ENTRY MONITOR...
  • Page 37 | Table of contents | PROGRAMMING VIA INSTALLER MENU √ The first time the door entry monitor is switched on, you will need to configure the device language; you will also be able to set the date and time if necessary. 1.
  • Page 38 | Table of contents | D I S PL A Y B U T T O N F U N CT IO NS MENU By selecting this menu, the functions currently assigned to the buttons on the door entry monitor are displayed. The factory-set functions are as follows: B A C K P R OGR A MMED FU NCTI ON...
  • Page 39 | Table of contents | EXAMPLE: PROGRAMMING THE INTERCOM FUNCTION TO OTHER APARTMENT 1. Press one of the following buttons to access the user menu. 2. Press for 5 sec to access the installer menu. 5 sec » A confirmation tone will sound and the following screen will appear. DISPLAY BUTTON FUNCTIONS INTERCOM ACTUATOR...
  • Page 40 | Table of contents | T O O TH ER APARTMENT 5. Press to select » The menu will turn green. B ACK TO OTHER APARTMENT TO SAME APARTMENT 6. Press the confirm button. 7. Press to select the number you want to change. »...
  • Page 41 | Table of contents | EXAMPLE: PROGRAMMING THE INTERCOM FUNCTION TO SAME APARTMENT 1. Press one of the following buttons to access the user menu. 2. Press for 5 sec to access the installer menu. 5 sec » A confirmation tone will sound and the following screen will appear. DISPLA Y BUTTON FU NCTIONS INTERCOM ACTUATOR...
  • Page 42 | Table of contents | T O S AM E APARTMENT 5. Press to select » The menu will turn green. B ACK TO OTHER APARTMENT TO SAME APARTMENT 6. Press the confirm button. 7. Press the button to be associated with the function. is configured to activate another function, the MyComelit app should be used to restore the video memo function.
  • Page 43 | Table of contents | INSTALLER MENU NAVIGATION TREE D I S PL A Y B U T T O N F U N CT IO NS Select this menu to view the functions currently assigned to the buttons on the door entry monitor. B A C K P RO GR A M M E D F U N C T I O N B U T TON...
  • Page 44 | Table of contents | A D V AN C ED Select this menu to access the advanced settings. D A T E FO RMAT Select this menu to configure the date display format. DD/MM/YYYY MM/DD/YYYY YYYY/MM/DD M A I N /SE CONDARY Select this menu to configure the door entry monitor as Main (default) or Secondary.
  • Page 45 | Table of contents | A D V AN C ED P A N I C CALL Select this menu to configure a button or the CFP input to transmit a priority call to the porter switchboard. PAIR WITH BUTTON PAIR WITH CFP INP UT S W I T CHB OARD CALL Select this menu to configure a button to make the call to standard or main porter...
  • Page 46 | Table of contents | PROGRAMMING VIA MYCOMELIT APP (VERS. 2.0.0 OR HIGHER) The MyComelit app can be used to program the door entry monitor quickly and easily, even while it is switched off. When the MyComelit app is used to configure the door entry monitor, the language, date and time are set automatically.
  • Page 47: Intercom Function

    | Table of contents | MAIN AND SECONDARY DOOR ENTRY MONITOR In systems with power supply unit art. 1210/1210A, one main door entry monitor and 3 secondary door entry monitors can be programmed for each apartment. In systems with power supply unit art. 4888C, 2 main door entry monitors and 2 secondary door entry monitors can be programmed for each apartment.
  • Page 48 | Table of contents | • Selective group intercom This is an intercom call to groups of several door entry monitors in the same apartment or another apartment identified by a dedicated intercom code, different from the user code. The door entry monitor button can be programmed with up to 3 different intercom codes to which the call will be made at once.
  • Page 49: Operating Distances

    4893M 4893M A MAX B MAX E MAX Art. 1216 Comelit Art. 4577/4579 1 mm² (Ø 1.2 mm AWG 17) 200 m 100 m (655 feet) (330 feet) UTP5 cat. 5 0.2 mm² (Ø 0.5 mm AWG 24) 100 m...
  • Page 50: Wiring Diagrams

    | Table of contents | Wiring diagrams LS8731 CFP CFP 110-240V 1209 4893M 12 VAC/VDC 18 Ω MAX Max. 20 m. Local door-opener button.
  • Page 51 | Table of contents | 1216 LS8731 CFP CFP LS8731 1214/2C CFP CFP LS8731 1214/2C CFP CFP LS8731 1214/2C CFP CFP 1214/2C LS9431V 110-240V 1209 4893M 12 VAC/VDC 18 Ω MAX Max. 20 m. Local door-opener button.
  • Page 52 | Table of contents | System expansion diagrams LS8731 1216 CFP CFP 1214/2C 20 m max LS8731 LS8731 CFP CFP CFP CFP 1214/2C In systems with power supply unit art. 1209, a maximum of 1 main door entry monitor (P) and 3 secondary door entry monitors (S) can be programmed for each apartment.
  • Page 53 | Table of contents | VIDEO ENTRY SYSTEM RISER 1209 L1 L1 L2 L2 110-240V 1405 4893M 12 VAC/VDC 18 Ω MAX 4893M 12 VAC/VDC 18 Ω MAX To program the entrance panel as Main or Secondary, refer to Programming an additional entrance panel. Max 20 m.
  • Page 54 | Table of contents | Max 20 m. Local door-opener button. The door open indication function is not available. The self-activation function is available (with toggle function between 2 external units).
  • Page 55 | Table of contents | Using the entrance panel relay on generic actuator control 1209 12 VAC/VDC 12V/24V 18 Ω MAX AC-DC 4A MAX 4893M C.NC.NO relay activation: 2 sec. (Default) 12 VAC/VDC 1209 18 Ω MAX The SE output and the C-NO relay are controlled by 2 separate buttons on 12 VAC/VDC the door entry monitor: the key button (SE) and the generic actuator button 1209...
  • Page 56 | Table of contents | Table of user codes code DIP ON 1,2,3,4,5 1,3,4,5,6 1,2,4,5,7 1,4,5,6,7 1,2,3,5,8 1,3,5,6,8 1,2,5,7,8 2,3,4,5,6 3,4,5,7 2,4,5,6,7 4,5,8 2,3,5,6,8 3,5,7,8 1,2,3,4,5,6 1,3,4,5,7 123 1,2,4,5,6,7 153 1,4,5,8 183 1,2,3,5,6,8 213 1,3,5,7,8 2,3,4,5,7 3,4,5,6,7 2,4,5,8 4,5,6,8 2,3,5,7,8 1,2,6 95 1,2,3,4,5,7 125 1,3,4,5,6,7 155 1,2,4,5,8...
  • Page 57 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m 1st edition 02/2024 Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy code 2G40003172...

This manual is also suitable for:

Ls9431v

Table of Contents