Technical Specifications - Lincoln Electric PRISM CENTRAL SYSTEM 2 Operator's Manual

Table of Contents

Advertisement

PRISM
CENTRAL SYSTEM 2
®

TECHNICAL SPECIFICATIONS

GENERAL
TYPE OF CLEANING
DUTY CYCLE
COMPRESSED AIR PRESSURE
AND QUALITY
FILTER CLEANING COMPRESSED AIR CONSUMPTION
Compressed Air pressure: 6 bar (87 psi)
*5 bar (72 psi) approx 20% less* volume
PAUSE TIME: 15 SEC (factory default "bold")
PULSE LENGTH: 250ms (factory default)
Air Consumption CFM, (L/MIN)
5
10
15
20
25
30
35
40
45
50
55
60
NOTE: Compressed air must be clean and dry, and have a dew point
of -40°F (-40°C).
FILTER CLASS (ACCORDING TO ASHRAE 52.2)
KP4519-1
KP4519-2
KP4519-3
KP4519-4
KP4519-5
AMBIENT CONDITIONS
MINIMUM TEMPERATURE
MAXIMUM TEMPERATURE
MAXIMUM RELATIVE HUMIDITY
Pulse jet
100%
72 - 87 psi (5 - 6 bar)
clean, dry and oil free
Cleaning Cycle
51.6 (1464)
25.8 (732)
17.2 (488)
12.9 (366)
10.3 (293)
8.6 (244)
7.4 (209)
6.5 (183)
5.7 (163)
5.2 (146)
4.7 (133)
4.3 (122)
MERV 11
MERV 16 NANO
MERV 16 PTFE
MERV 11 OIL RESISTANT
MERV 16 OIL RESISTANT NANO
-4°F (-20°C)
113°F (45°C)
75%
PRISM
®
2: AD1326-25 & AD1326-26
INPUT VOLTAGE
NOMINAL +/- 10%
MAXIMUM CURRENT (NOMINAL)
MOTOR POWER (NOMINAL)
INSULATION CLASS FAN
MOTOR
PROTECTION CLASS FAN
MOTOR
DIMENSIONS
FAN SUPPLY FUSE
ALARM LEVEL
TECHNICAL SPECIFICATIONS
380-480V/3~/50-60Hz (FAN)
115-230V/1~/50-60Hz (CONTROLS)
5.9A (FAN)
2A (CONTROLS)
5.8 HP
F
IP54
See Section F
CLASS J OR CC 10A/600V
1500Pa (factory default)

Advertisement

Table of Contents
loading

This manual is also suitable for:

1365513656

Table of Contents