PRISM
CENTRAL SYSTEM 2
®
INSTALLATION
GENERAL DESCRIPTION
®
Prism
2 is a reduced-footprint fan/filtration unit combination
designed with robotic welding and plasma cutting system in
mind. The 2-filter configuration can provide extraction capacity
for just about any automated system equipped with a hood.
Pre-assembly allows for easy and quick installation.
of compressed air shots, resulting in the particulate dropping into
a dustbin at the bottom of the unit.
THE INTENDED PURPOSE
Extraction of fumes that are released in the course of using
welding equipment for cutting and joining non-alloy and alloy
steels, including highalloy chromium/nickel steels with a nickel
and chromium content of ≥ 30%
TRANSPORT AND ERECTION
Instruct all persons whose presence is not
required to stay out of the hazard area
Do not stand under or next to the load when it is being
lifted up or set down
Transport the unit or erection components on the pallets
provided, and secure them against falling over or
slipping.
Transport them with a suitable pallet truck or forklift
truck
Taller units should be built up on site
Filter units must be secured to the foundations
The foundations must have adequate load-bearing
strength and be free of vibration
•
The installer is responsible for following
federal, state and local safety codes and
regulations.
•
Before drilling, verify locations of existing
gas, water or electrical conduits.
Excluded Uses!
•
Welding fumes containing oil
•
Aluminium dust
•
Burning or incandescent materials
•
Cigarettes
•
Aggressive media
•
Water and moisture
•
Explosive gases and/or dust mixtures
•
Dusts with toxic characteristics other than welding
fumes
•
The installation of this product is exclusively reserved
electrical and mechanical contractors. A goal of the
Smartwire is quick installation, possibly without any LE
involvment.
•
Inspect the product and check it for damage. Verify the
functioning of the safety features.
•
Electrical connection to be executed in accordance
with local requirements. Ensure compliance with the
EMC regulatory arrangements.
•
Check the working environment. Do not allow
unauthorized persons to enter the working
environment.
•
Protect the product against water and humidity.
•
Use common sense. Stay alert and keep your attention
to your work. Do not use the product when you are
•
Ensure the workspace is well-illuminated.
•
Never install the product in front of entrances and exits
which must be used for emergency services.
•
Make sure that the workshop, in the vicinity of the
•
Make sure the wall, ceiling or support system are
strong enough to carry the product.
•
Air containing particles such as chromium, nickel,
beryllium, cadmium, lead etc., which is a health hazard,
should never be recycled. This air must always be
brought outside the working area.
SELECT SUITABLE LOCATION
• Do not place equipment near radiant heat sources.
of clearance around machine at all times for maintenance
requirements.
ENVIRONMENTAL AREA
Keep the machine inside and dry at all times. Do not place on wet
ground or in puddles. Never place liquids on top of the machine.
INSTALLATION