Active front end (afe) afe rectifier / regenerative feedback unit ac-dc modular design for construction types e to j
Table of Contents

Advertisement

01.2004
12.14

Profile parameters

PNU
Parameter Name in OP1
*:conf-P
Description
P918
CB Bus Address
Protocol-dependent bus address for communication boards: see
396Hex
board documentation
Note:
The validity of the bus address is monitored by the
Com Board. If its value is not accepted by COM
BOARD, fault F080 with fault value 5 is displayed
Precondition: P090 = 1 or P091 = 1 (Communication board
logged on)
Type=O2;
PKW: 1HEX=1.0
P927
Parameter Access
*
Enabling of interfaces for parameterization
39FHex
See P053 for description.
Type=O2;
PKW: 1HEX=1.0
P928
Src Base/Reserve
*
Source for basic/reserve setting switchover command (control
3A0Hex
word 2, bit 30); this parameter is identical to P590.
See P590 for description.
Type=L2; PKW: PKW format(HEX)=param.value
Siemens AG
6SE7087-6CX86-2BA1
SIMOVERT MASTERDRIVES AFE
PZD Gr.: -
PZD Gr.: -
PZD Gr.: 0
Operating Instructions
Range
# of Indices
[Unit]
Factory
Value Texts
Settings
0 to 200
3
0 to 31
6
0 to 5001
1005
Parameter List
read:
_/_
write:
_/_
3 / H BR
3 / H
3 / BR
3 / BR
3 / BR
3 / BR
12-35