HP CX 6300 Installation And Getting Started Manual page 19

Table of Contents

Advertisement

Fan requirements
Switches
JL658A
JL659A
JL663A
JL664A
JL660A
JL661A
JL662A
JL762A
R8S89A
R8S90A
R8S91A
R8S92A
S0E91A
S0X44A
For JL660A, JL661A, JL662A, JL663A, and JL664A:
Fan Condition
Fan Speed
System installed with 2 fan trays
4 fans functioning
According to ambient and
normally
component temperature
1 fan fault
Remaining fans will spin at Max
speed
More than 1 fan
Remaining fans will spin at Max
fault
speed
System installed with 1 fan tray
2 fans functioning
According to ambient and
normally
component temperature
1 fan fault
Remaining fans will spin at Max
speed
Fan Tray 1
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Fan Redundancy
N+1
Not supported
Not supported
Not supported
Not supported
Fan Tray 2
Required
Required
Optional
Optional
Optional
Optional
Optional
Required
Required
Required
Required
Required
Required
Required
Shutdown
Component hits thermal limit
Component hits thermal limit
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit
Component hits thermal limit
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit
Introducing the switches |