ELECTRICAL CONNECTIONS

-
Three-phase 400V power supply without neutral – 50 Hz
-
Compressed air supply 5 Bars minimum.
Electrical requirements
POWER
230V mono
(kW)
0,18
3x1,5
0,25
3x1,5
0,37
3x1,5
0,55
3x1,5
0,75
3x1,5
1,1
3x1,5
1,5
3x1,5
2,2
3
4
30
Part numbers of cables
Cable section
3x1.5 mm²
W000010098
3x2.5 mm²
W000010099
4x2.5 mm²
W000010100
4x4 mm²
W000010101
4x6 mm²
W000010102
4x10 mm²
W000010103
4x16 mm²
W000010104
4x25 mm²
W000010105
4x35 mm²
W000010106
MODULO MD2 extraction units are wired for 400V in the factory (motor and auxiliary transformer).
If your company system is three-phase 230V, you must modify the connections of the motor terminal plate and the
auxiliary transformer in the electrical cabinet.
MODULO MD2
All the operations relating to the installation, such as those for
assembly, installation, putting into service and maintenance, are
to be carried out by qualified personnel under the control of a
responsible technician.
50HZ SYSTEM VOLTAGE
230 3PH
400 3PH
Section (mm²)
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x2,5
4x2,5
4x2,5
Part number
Before making the connections, check the system voltage and
wire the extraction unit accordingly.
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x1,5
4x16
-11