MAINTENANCE OF MECHANICAL PARTS

The machine requires negligible mechanical maintenance if it is used correctly in accordance with its technical
characteristics.
Before any type of maintenance that is not clearly defined in these instructions, please make inquiries with the
technical department of LINCOLN ELECTRIC.
The performance of operations that have been defined as "not feasible" or are contrary to the standards and
procedures described in the "General Instructions" section would release LINCOLN ELECTRIC from liability for any
damage caused and would void the guarantee if it is still valid.

PRE-FILTER MAINTENANCE

Periodically, as a preventive measure, or whenever extraction does not seem adequate :
Clean with dry compressed air or immerse in a solution made of water and + FILTER CLEAN 20L part number
W000342878.
Then dry with air

FILTER CARTRIDGE MAINTENANCE

When the MODULO MD2 extraction unit is fitted with the optional filter cartridge and compressed air supply kit,
unclogging cycles must be carried out from time to time with the dedicated pushbutton.
That will remove welding fume particles from the cartridge and maintain the regulatory extraction level at the welding
torch.
-
Run unclogging cycles once the work is complete
Leave the dust to rest in the container
-
Empty the container in dedicated skips, as welding and cutting dust must be recycled