11-4 Derating Curve

Protection Level
UL Type 1/ IP20
UL Open Type/ IP20
Ambient Temperature Derating Curve
460V
100
90
80
70
60
50
30
IP20 UL Open Type/ IP00 Chassis
IP20 UL Open Type or IP00 Chassis:
The rated output current derating (%) when carrier frequency is the default value:
Ambient Temp. (Ta)/
100% Load
Carrier Frequency (kHz)
Default
IP20 UL Type 1:
The rated output current derating (%) when carrier frequency is the default value:
Ambient Temp. (Ta)/
100% Load
Carrier Frequency (kHz)
Default
If the AC motor drive operates at the rated current, the ambient temperature needs to
be between -10– +40°C. If the temperature is above 40°C, decrease 2% of the rated
current for every 1°C increase in temperature. The maximum allowable temperature is
60°C.
If the AC motor drive operates at the rated current, the ambient temperature needs to
be between -10– +50°C. If the temperature is above 50°C, decrease 2% of the rated
current for every 1°C increase in temperature. The maximum allowable temperature is
60°C.
Derating for Ambient Temperature
35
40
Ambient Temperature (° C )
30°C
100
30°C
100
Operating Environment
45
50
IP20 UL Type 1
50°C
100
45°C
100
697
Chapter 11 Specification | VP3000
55
60
Figure 9-1
60°C
80
60°C
70
Table 9-5