Zoning The Dehumidifier; Required Components - Aprilaire E080 Installation & Owner's Manual

80 & 100 ppd professional-grade, whole-house dehumidifiers
Hide thumbs Also See for E080:
Table of Contents

Advertisement

3. Wire the FAI damper, HVAC equipment and outdoor
temperature sensor to the dehumidifier control as shown in
FIGURE 27
FIGURE 27: VENTILATION WIRING
+ - A B
Remote
A
C
B
A. OPTIONAL OUTDOOR TEMPERATURE SENSOR (MODEL 8052)
B. 6" NORMALLY CLOSED DAMPER OR 8190FF
C. 24 VAC (10 VA MIN) TRANSFORMER
(E100V: USE EXTERNAL 24V PORT)
4. Use the setup menu to ENABLE ventilation:
a. Enter the installer setup menu (see page 16)
b. Press the Mode button until the words VENT DISABLE
appear
c. Press the
button to change to VENT ENABLE
or
d. Press the Mode button and the words VENT TIMED will
appear Press the
or
limits:
i. TIMED: no temperature limits
ii. AUTO – B: Ventilation is not allowed if the ODT > 100°F or
ODT < 0°F; ventilation is allowed only when the heat is
on if the ODT is between 0°F and 20°F
iii. AUTO – C: Ventilation is not allowed if the ODT > 100°F or
ODT < 0°F
iv. AUTO – D: Ventilation is not allowed if the ODT > 90°F;
ventilation is allowed only when the heat is on if the
ODT is between 0°F and 40°F
e. Press the Mode button and then use the
to set the ventilation time (minutes/hour)
f. Press the Mode button repeatedly until the word DONE
appears on the display
Whenever the heating, cooling or dehumidifier is active, the
ventilation damper will open and bring in outdoor air If the
equipment doesn't run for the set number of minutes, the
dehumidifier will turn on the HVAC fan at the end of the hour to
ensure ventilation needs are met
ODT
VENT DEH
Sensor Dampers
THERMOSTAT
OR ZONE
HVAC
CONTROL
EQUIPMENT
BOARD
Y
W
W
C
R
G
button to set temperature
or
button
The dehumidifier can be configured to condition two
independent spaces Zoning requires the installation of
ductwork and dampers to direct air to and from two locations
NOTE: Dehumidifier zoning is not recommended in HVAC zoning
applications
In this installation the dehumidifier controls the humidity
in two separate zones, a Primary and Secondary Zone The
dehumidifier will dehumidify the Primary Zone as the first
priority and will switch to the Secondary Zone after the
dehumidification needs of the Primary Zone have been
satisfied.
IMPORTANT: Normally Closed dampers must be installed in the
ducts serving the Primary Zone and Normally Open dampers
installed in the ducts serving the Secondary Zone

REQUIRED COMPONENTS

Y
• 10" ductwork and fittings
G
C
R
• Grilles with 10" duct collars
• Drain line
• (2) AprilAire Model 6510, 10" Normally Closed damper
• (2) AprilAire Model 6610, 10" Normally Open damper
90-1861
• 24 VAC transformer (40 VA min) for dampers
NOTE: 5442 Basement Kit includes (2) 6510 Dampers,
(2) 6610 Dampers and a 24 VAC (40 VA) transformer

ZONING THE DEHUMIDIFIER

15

Advertisement