Table Of Contents; Specifications - Aprilaire E080 Installation & Owner's Manual

80 & 100 ppd professional-grade, whole-house dehumidifiers
Hide thumbs Also See for E080:
Table of Contents

Advertisement

SPECIFICATIONS                                                     2
SAFETY INSTRUCTIONS                                              3
WHOLE HOME DEHUMIDIFICATION                                  3
OPERATING THE DEHUMIDIFIER                                     4
Energy Savings Tips                                              4
MAINTENANCE                                                       5
Cleaning the Filter                                               5
Cleaning the Drain                                               5
PREPARING THE UNIT FOR INSTALLATION                           6
Installing the Duct Collars                                       7
INSTALLING THE DEHUMIDIFIER                                     8
Dehumidifier Location                                           8
Leveling and Raising the Dehumidifier                          8
Installing the Drain                                               9
INSTALLING DUCTWORK                                            9
to the HVAC System                                             10
Ducting the Dehumidifier Outlet to the HVAC System
with Dedicated Dehumidifier Inlet Register                     11
WIRING                                                             12
Wiring to the HVAC System                                     12
Wiring to External or Remote Controls                         13
Wiring to a Float Switch                                         13
Unit Weight
Capacity
80°F, 60% RH Conditions
Power
115 VAC, Single Phase, 60 Hz
Dehumidifier Inlet Air Conditions
Filter
Airflow
NOTE: Rated capacity and current draw measured at 80°F/60% RH inlet conditions at 00 external static pressure
2

TABLE OF CONTENTS

VENTILATION                                                        14
ZONING THE DEHUMIDIFIER                                        15
Required Components                                         15
INSTALLER SETUP                                                   16
Crawl Space/Sealed Attic                                      17
Enabling DEH w/AC                                              17
INSTALLER TEST MODE                                              18
Dehumidification Only                                          18
Zoning and/or Ventilation                                      18
Using the Dehumidifier Control Only                           19
Using a Model 76 as a Remote Control                        19
Using an External Control                                       19
Two-Zone Operation                                            19
SERVICE PARTS                                                     23
LIMITED WARRANTY                                                24
Warranty Registration                                          24

SPECIFICATIONS

Model E080 and E080H
63 lbs
80 pints per day @ 185 CFM
51 A operating current
Dehumidification: 50°F-104°F, 40°F dew point minimum
Ventilation: 40°F-140°F, 0% RH-99% RH (non-condensing)
External Static
Pressure ("w.c.)
Airflow (CFM)
00
02
04
Installation not advised
Model E100, E100C, and E100H
100 pints per day @ 280 CFM
69 A operating current
MERV 8, washable
External Static
Pressure ("w.c.)
185
00
135
02
85
04
06
64 lbs
Airflow (CFM)
280
245
210
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

E100E100cE100h

Table of Contents