Installer Setup - Aprilaire E080 Installation & Owner's Manual

80 & 100 ppd professional-grade, whole-house dehumidifiers
Hide thumbs Also See for E080:
Table of Contents

Advertisement

FIGURE 28: WHOLE-HOME PRIMARY ZONE INSTALLATION
B
A
G
A. RETURN FROM SECONDARY ZONE
B. NORMALLY CLOSED DAMPERS
C. RETURN DUCT
D. TO/FROM PRIMARY ZONE
FIGURE 29: TWO-ZONE WIRING ON-BOARD CONTROL
B
C
+ - A B
ODT
VENT DEH
A
F
A. FLOAT SWITCH
E. HVAC EQUIPMENT
B. REMOTE
F. 24 VAC (40 VA MIN)
C. SENSOR
G. NORMALLY CLOSED (PRIMARY ZONE)
D. DAMPERS
H. NORMALLY OPEN (SECONDARY ZONE)
16
E
D
C
6
FEET
MIN
G
E. SUPPLY DUCT
F. SUPPLY TO SECONDARY ZONE
G. NORMALLY OPEN DAMPER
D
E
G
H
Enter the setup menu if:
• the dehumidifier is ducted to the HVAC system
• an external or remote control will be used
• ventilation or zoning will be used
1. Plug unit in and turn power switch ON (if equipped)
F
2. The onboard control screen should display OFF If not OFF,
press the ON/OFF button to turn the unit OFF
NOTE: If the display backlight is not on, the first button press
(any button) will only turn on the backlight Press the button a
90-1875
second time to achieve function
3. Hold the MODE button on the onboard control for 3 seconds
to enter the installer setup menu
4. Navigate through the following screens to set up the
dehumidifier for the installed application.
5. Use the
or
button to switch to the next setup option To exit the installer
setup, scroll through all options using the MODE button
6. After the installer setup options have been completed, the
word DONE will blink for 3 seconds and the control will return
to the OFF screen
90-1896

INSTALLER SETUP

button to select items and use the MODE