Advertisement

SAFETY INSTRUCTIONS

1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
3. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
3. Do not use in pool applications. Pool chemicals can damage the dehumidifier.
4. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
5. Wait 24 hours before running the unit if it was not shipped or stored in the upright position
6. Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower
indoor humidity in the winter.
7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
8. Children should be supervised to ensure that they do not play with the appliance.
9. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

TABLE OF CONTENTS

SAFETY INSTRUCTIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1
SPECIFICATIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
REMOVE SHIPPING BRACKET � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
LOCATION CONSIDERATIONS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
DRAIN INSTALLATION � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
Condensate Pump and Float Switch � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
SETTING THE DESIRED HUMIDITY LEVEL � � � � � � � � � � � � � � � � � � � � � � � � � 4
MAINTENANCE� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
Model E130C Dehumidifier
Installation and Operating Manual
WARNING
CAUTION
READ AND SAVE THESE INSTRUCTIONS
DUCT COLLAR INSTALLATION� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
Control Location� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
DUCTING � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Ducting in Basement � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Ducting to Whole Home without an Air Handler� � � � � � � � � � � � � � � � � � 8
TROUBLESHOOTING � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Table 1 - Diagnostic Codes � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Table 2 - Troubleshooting Guide � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
SERVICE PARTS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �11
LIMITED WARRANTY � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 12
1

Advertisement

Table of Contents
loading

Summary of Contents for Aprilaire E130C

  • Page 1: Table Of Contents

    Model E130C Dehumidifier Installation and Operating Manual SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power disconnected until installation/service is completed. 2. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
  • Page 2: Specifications

    SPECIFICATIONS MODEL E130C Unit Weight 98 lbs� Shipping Weight 115 lbs� Capacity 130 pints per day @ 310 CFM 80°F, 60% RH Conditions Power 8�3A operating current 115 VAC, Single Phase, 60Hz Dehumidification: 50°F – 104°F, 40°F dew point minimum Dehumidifier Inlet Air Conditions Ventilation: 40°F –...
  • Page 3: Location Considerations

    LOCATION CONSIDERATIONS • Allow sufficient clearance for filter removal and to prevent airflow obstruction FIGURE 2 – FILTER ACCESS CLEARANCE • Electrical service access will require the removal ELECTRICAL SERVICE ACCESS THIS SIDE of the side panel shown� Allow sufficient space 6"...
  • Page 4: Setting The Desired Humidity Level

    SETTING THE DESIRED HUMIDITY LEVEL 1. Plug in dehumidifier and turn on/off switch ON� See FIGURE 4� FIGURE 4 – ON/OFF SWITCH 2. Press the ON/OFF button to turn the dehumidifier control ON� The display will show the current setting, and the dehumidifier blower will turn on to start sampling the air� 3.
  • Page 5: Maintenance

    MAINTENANCE CLEAN OR REPLACE THE AIR FILTER After initial installation the air filter should be checked and cleaned every 6 months� The CLEAN FILTER service reminder will display on the on-board control screen every 6 months� To clear the service message, press the buttons simultaneously for 3 seconds�...
  • Page 6: Duct Collar Installation

    DUCT COLLAR INSTALLATION HORZONTAL DISCHARGE: • Use the screws in the parts bag to attach the duct collars to the FIGURE 7 – FULLY DUCTED INSTALLATIONS inlet and outlet of the dehumidifier� The outlet collar has a backflow OUTLET COVER damper�...
  • Page 7: Ducting

    DUCTING DUCTING IN BASEMENT The dehumidifier can be ducted to pull air from and return dehumidified air to the HVAC return duct� This installation will ensure warm, dehumidified air is thoroughly mixed with the HVAC system air before being discharged into the living space� Alternatively, the dehumidifier can be ducted to discharge to the supply duct, but the external static pressure of the HVAC system must not exceed 0�7 "w�c�...
  • Page 8: Ducting To Whole Home Without An Air Handler

    DUCTING TO WHOLE HOME WITHOUT AN AIR HANDLER In this installation the dehumidifier is not ducted to the HVAC system� FIGURE 12 – STAND ALONE DUCTED REQUIRED COMPONENTS: • 10" Ductwork DEHUMIDIFIED AIR IS SUPPLIED TO DUCTED SPACE • Grilles with 10" Duct Collars DEHUMIDIFIED SPACE 10' MIN AIR IS PULLED FROM...
  • Page 9: Troubleshooting

    TROUBLESHOOTING Technical Support is available Monday through Friday, 7:00 a�m� to 5:00 p�m� CST, at (800) 334-6011� Use the guides on the following pages to identify and correct system faults� Contact Technical Support before replacing the unit or any components and for additional troubleshooting� DIAGNOSTIC CODES When an error occurs, the Diagnostic Code along with SERVICE REQUIRED will be displayed on the control screen�...
  • Page 10 TABLE 1 – DIAGNOSTIC CODES Diagnostic Code Failure Mode Action Reset 1. Empty the condensate pan� 2. Check the float switch connection at the control board� Float Switch Open Self-Correcting 3. If not using a float switch, verify jumper is between float switch terminals on dehumidifier control board�...
  • Page 11: Service Parts

    SERVICE PARTS 90-2031 Part Description Part No. Part Description Part No. Filter, 14" x 19" x 1" EZK 5569 Cover, Outlet, AA Deh 5452 Internal Control Board, Deh 5444 Fan, 130pt Deh, with 10MFD Capacitor 5572 User Interface Assembly, Deh 5445 Wire Harness, Power, Deh 5454...
  • Page 12: Limited Warranty

    WARRANTY REGISTRATION Visit us online at www.aprilaire.com to register your Aprilaire product� If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P�O� Box 1467, Madison, WI 53701�...

Table of Contents