Action when data transfer fails

• If "NG" appears on the control panel, indicating that rewriting has been unsuccessful (in
which case the Start key lights up red), take the following steps.
1. Perform the data rewriting procedure again.
2. If the procedure is abnormally terminated, change the USB memory for a new one and
try another rewriting sequence.
3. If the procedure is still abnormally terminated, change the board that has caused "NG"
and carry out data rewriting procedure.
F/W to be updated
MFP CONTROLLER
SCANNER/PRINTER
DSC1
DSC2
ADF (DF-M)
FINISHER
SD
FAX BOARD CONTROLLER1 FAX board/1 (FAXB/1)
FAX BOARD CONTROLLER2 FAX board/2 (FAXB/2)
FAX BOARD CONTROLLER3 FAX board/3 (FAXB/3)
FAX BOARD CONTROLLER4 FAX board/4 (FAXB/4)
Appropriate board
eMMC board (eMMC)
MFP board (MFPB)
DSC board/1 (DSCB/1)
DSC board/2 (DSCB/2)
DF control board (DFCB)
FS control board (FSCB)
-
42
10. Firmware rewriting
Remark
-
-
Only when SC-508 is mounted
Only when SC-508 is mounted
-
Only when FS-536 or FS-536SD is
mounted
Only when FS-536SD is mounted
Only when FK-514 is mounted
Only when FK-514 is mounted
Only when FK-515 is mounted
Only when FK-515 is mounted